Dunkirk 95M-200 Parameter Manual page 5

Gas-fired direct vent modulating hot water boiler
Table of Contents

Advertisement

DEFAULT PARAMETER SETTINGS ON GASCOM SOFTWARE AND BOILER DISPLAY
DO NOT CHANGE ANY PARAMETER UNLESS THE APPLICATION REQUIRES SPECIAL SETTINGS.
PARAMETER/DESCRIPTION
1
T3 Set DHW
2
DHW System
3
CH System
4
T1 Top CH-Mode
5
T1 Foot CH-Mode
6
T4 Minimum
7
T4 Maximum
8
T4 Frost Protection
9
T4 Correction
10
T Blocking
11
Booster Time
12
T Parallel Shift
13
Maximum Fan Speed CH
15
Maximum Fan Speed DHW
17
Minimum Fan Speed
19
Ignition Fan Speed
20
CH Postpump Time
21
DHW Postpump Time
22
CH Modulation Hysteresis On
23
CH Modulation Hysteresis Off
24
DHW Modulation Hysteresis On
25
DHW Modulation Hysteresis Off
26
DHW Detection Hysteresis On
27
DHW Detection Hysteresis Off
28
CH Blocking Time
29
DHW Blocking Time
30
DHW -> CH Blocking Time
31
Modulate Back Difference T1 - T2
32
RMCI Address
33
T Plus: Setvalue Additional For DHW
34
2nd CH-Circuit (1st Digit)
34
CH Type (2nd Digit)
35
DHW 3-Way Valve/Pump (1st Digit)
35
DHW Type (2nd Digit)
36
Manual Fan Speed
37
PWM-Pump Level (1st Digit)
37
PWM-Pump Level (2nd Digit)
38
T Set Hold Boiler Warm
39
T Top For 2nd CH Circuit
40
T Foot for 2nd CH Circuit
41
T Hysteresis For 2nd CH Circuit
42
Pump Settings For CH & DHW
42
Minimum Off Cycle
GASCOM
150°F
On
On
180°F
120°F
0°F
60°F
-20°F
0°F
60°F
30 Minutes
10°F
4600 rpm
4600 rpm
2150 rpm
4300 rpm
0 Minutes
30.6 Seconds
4°F
4°F
4°F
4°F
4°F
4°F
10.2 Seconds
10.2 Seconds
30.6 Seconds
50°F
-01
30
2nd CH-Circuit Off
Room Thermostat
Hot Water Pump
Storage Tank w/out Tank
Sensor (NTC3)
Negative 1%
3
1
40°F
70°F
50°F
20°F
00
Not Active
5
DISPLAY
150
01
01
180
120
00
60
-20
00
60
30
10
46
46
21
43
00
03
04
04
04
04
04
04
01
01
03
50
-01
30
00
00
13
13
-01
31
31
40
70
50
20
21
21