Manual Operation; Restarting After Starting Failure; Electric Operation - Yanmar 2GM20(F)(V)(C) Operation Manual

Marine diesel
Table of Contents

Advertisement

3. Operation
Manual Operation (Seawater Cooling
Only)
1.
Open
the Kingston
cock.
2. Open
the
fuel tank cock.
3.
Set
the
remote
control
lever
in
NEUTRAL
4.
Pull out the decompression lever.
5.
Put the starter handle on the starter
shaft,
align the groove and pin, and
turn by hand. When you begin turning,
you
will hear the sound of fuel being
injected.
6. Turn
the handle vigorously. When the
rotation
is
rapid,
return the decom-
pression lever to original
position.
The
engine
starts.
7.
Remove the
starter
handle from the
starter shaft.
Q)
Decomp.
lever
@
Drive
@
Decompression
28
M
anual
start
position
(2)
Restarting After
Starting Failure
Before pushing the start button
again,
be
sure to confirm that the engine has
stopped completely.
If the engine is
restarted while the engine still has not
stopped, the pinion gear of the starter
motor will be
damaged.
Electric Operation
~~
rl.
••
::.,;
Do not
hold the
start button on
for
more than 15
seconds at a
time.
If
the
engine
does
not start
the
first
time,
wait
for about 15
seconds
before trying
again.
After the
engine
has
started, do
not turn
the key
off.
(It
should
remain
ON.)
Alarm devices will not work
when
the key is
OFF.
(3)
Air Venting
of
the Fuel
System
After
Starting
Failure
If the engine only idles and won't start after
several
attempts, there may be air in the
fuel system. If air
is in
the fuel system, fuel
cannot reach the fuel
injection
pump. Vent
the air
in
the system according to
the
following procedures.

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

3gm30(f)(v)(c)

Table of Contents