Figure 5 — Connect Battery Charge Cables
• Connect battery charge cable clamp attached to the
black lead to the negative (–) battery terminal
(Figure 5).
• Start engine. Let the engine run while battery recharges.
• When battery has charged, shut down engine.
NOTE: Use an automotive hydrometer to test battery
state of charge and condition. Follow the hydrometer
manufacturer's instructions carefully. Generally, a battery is
considered to be at 100% state of charge when specific
gravity of its fluid (as measured by hydrometer) is 1.260 or
higher.
Generac Portable Products 10,000EXL Generator
RECEPTACLES
This generator is equipped with the following receptacles:
120 Volt, 20 Amp, Duplex
Black lead
Each of these outlets is protected against overload by
20 Amp push–to–reset circuit breakers. Use each outlet to
operate 120 Volt, 60 Hz, single phase loads requiring
2,400 (2.4 kW) watts at 20 Amps of current (Figure 6).
9
Receptacle
Figure 6 — 120 Volt, 20 Amp Duplex Receptacle