Generac Portable Products 10000EXL Owner's Manual page 11

Table of Contents

Advertisement

120/240 Volt, 30 Amp Locking Type
Receptacle
Use a NEMA L14–30 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 30 Amps
(or greater) (Figure 9). You can use the same 4–wire cord
if you plan to run a 120 Volt load.
Figure 9 — 120/240 Volt, 30 Amp, Locking Receptacle
This receptacle powers 120/240 Volt AC, 60 Hz, single
phase loads requiring up to 3,600 watts of power (3.6 kW)
at 30 Amps for 120 Volts AC; 7,200 watts of power
(7.2 kW) at 30 Amps for 240 Volts AC. The outlet is
protected by a 30 Amp push–to–reset circuit breaker.
Generac Portable Products 10,000EXL Generator
240 Volt, 50 Amp Receptacle
Use a NEMA 14–50 plug with this receptacle. Connect a
4–wire cord set rated for 250 Volt AC loads at 50 Amps to
the plug (Figure 10).
Use this receptacle to operate 240 Volt AC, 60 Hz, single
phase loads requiring up to 10,000 watts (10.0 kW) of
power.
11
Figure 10 — 120/240 Volt, 50 Amp, Receptacle
CAUTION!
Although this outlet states it has a
240 Volt 50 Amp rating (up to 12,500 watts), the
generator is only rated for 10,000 watts. Powering
loads that exceed the wattage/ amperage capacity of
the generator can damage it or cause serious
injuries.