Step-By-Step Installation Of The System; Finishing Materials; Horizontal Termination; Assembling Chimney Sections - Heatilator GC300 series Owner's Manual

Direct vent heat circulating series gas appliance
Table of Contents

Advertisement

GC300/GC400
SERIES
DIRECT
VENT
GAS
APPLIANCE
.1""""""
NON-COMBUSTIBLE
FINISHING
MATERIAL
ONL Y MAYBE
APPLIED
NON-
DRY WALL LIP
TO THE BLACK FACE
;
COMBUSTIBLE
518" DEEP
OF THE UNIT BUT
~ ;
SEALANT
~
UST NEVER COVER
THE GRILLES.
..:':'::.:.~:,'.'
I
~
COMBUSTI
~
BLE'
,
FINISHING
-"
MATERIAL.
.'..
'":'
'~
'I
>GRILLES
v
Figure 3
Finishing
Materials
WARNING
GRILLES ON THIS APPLIANCE
CANNOT,
IN ANY WAY, BE COVERED
AS IT MAY
CREATE A FIRE HAZARD.
THE SYSTEM
~
WARNING
BEFORE STARTING, DO THE FOLLOWING:
1.
WEAR GLOVES AND SAFETY GLASSES FOR PROTECTION.
2.
KEEP HAND TOOLS IN GOOD CONDITION.
SHARPEN CUTTING EDGES AND
MAKE SURE TOOL HANDLES ARE SECURE.
3.
ALWAYS MAINTAIN THE MINIMUM AIR SPACE REQUIRED TO THE ENCLOSURE TO
PREVENT FIRE.
sides. These clearances must be maintained at all
times. The maximum horizontal run allowed for
venting is 26 feet. The maximum vertical rise
allowed for horizontal termination is 25 feet. See
Figure 5.
1. Assembling
chimney
sections.
Attach either a
159428 (starter elbow) or straight pipe section
(depending upon your specific installation) to the
top of the appliance.
Secure with the three screws
supplied.
Use only pipe supplied and listed for use
with this appliance and the appropriate number of
direct vent sections.
MAINTAIN MINIMUM ClEAR-
ANCES OR GREATER AROUND THE CHIMNEY
SYSTEM.
Do not pack air spaces with insulation or
other material.
~
STEP 1 -Positioning
the firebox
This fireplace may be placed on a combustible or
non-combustible
continuous, flat surface.
Slide the
unit into position and level the fireplace from side-to-
side and front-to-back.
Shim with non-combustible
material, such as sheet metal, as necessary.
Secure the fireplace by bending out the nailing
flanges located on each side of the fireplace and
nailing the unit to the framing.
See Figure 4.
STEP 2 -Termination
Two types of termination are available for this appli-
ance, horizontal and vertical.
For vertical termina-
tion, skip section A and advance to section B on
page 11.
A.
Horizontal
Termination
Minimum combustible clearances to the vent on a
horizontal run is 3" on top and 1 " on the bottom and
23131A
12-94
9
v.
STEP-BY-STEP
INSTALLATION
OF
F. FINISHING
MATERIALS
Only non-combustible
materials may be used to
cover the black fireplace front.
Combustible
Finishing
Material.
Material made
of or surfaced with wood, compressed paper, plant
fibers, plastics, or any material capable of igniting
and burning, whether flame proofed or not, plas-
tered or unplastered.
Non-combustible
Finishing
Material.
Material
which will not ignite and burn. Such materials are
those consisting entirely of steel, iron, brick, tile,
concrete, slate, glass or plasters, or combination
thereof, or have UL Fire rating of Zero (0).
High Temperature
Sealant Material.
Sealants
that will withstand high temperatures;
General
Electric RTV1O3 (Black), or equivalent.
Rutland,
Inc. Fireplace Mortar #63, or equivalent.
After completing the framing and applying the fin-
ishing material (dry wall) over the framing, a non-
combustible sealant, one-half inch wide maximum,
must be used to close off any gaps at the top and
sides between the fireplace and facing to prevent
cold air leaks. See Figure 3.