15/20/25 Amp Battery Charging Systems

NOTE: Always zero ohmmeter on each scale before testing to ensure accurate readings. Voltage tests should be
made with engine running at 3600 RPM with no load. Battery must be good and fully charged.
When problems occur in keeping battery charged or battery charges at high rate, charging system or battery might be
causing problems.
To test charging system for no charge to battery:
1. Insert an ammeter in B+ lead from rectifier-regulator.
With engine running at 3600 RPM and B+ (at
terminal on rectifier-regulator) to ground using a DC
voltmeter.
If voltage is 13.8 volts or more, place a minimum
load of 5 amps (turn on lights if 60 watts or more, or
place a 2.5 ohm, 100 watt resistor across battery
terminals) on battery to reduce voltage. Observe
ammeter.
Condition
Charge rate increases
when load is applied.
Charge rate does not
increase when load is
applied.
2. Remove connector from rectifier-regulator. With
engine running at 3600 RPM, measure AC voltage
across stator leads using an AC voltmeter.
Condition
Voltage is 28 volts or
more.
Voltage is less than 28
volts.
3. With engine stopped, measure resistance across
stator leads using an ohmmeter.
Condition
Resistance is 0.1/0.2
ohms.
Resistance is 0 ohms.
Resistance is infinity
ohms.
4. With engine stopped, measure resistance from each
stator lead to ground using an ohmmeter.
Condition
Resistance is infinity ohms
(no continuity).
Resistance (or continuity)
measured.
24 690 06 Rev. J
Conclusion
Charging system is OK
and battery was fully
charged.
Test stator and rectifier-
regulator (steps 2 and 3).
Conclusion
Stator is OK. Rectifier-
regulator is faulty; replace.
Stator is faulty; replace.
Test stator further using an
ohmmeter (steps 3 and 4).
Conclusion
Stator is OK.
Stator is shorted; replace.
Stator is open; replace.
Conclusion
Stator is OK (not shorted
to ground).
Stator leads are shorted to
ground; replace.
KohlerEngines.com
To test charging system for battery continuously charging
at high rate:
1. With engine running at 3600 RPM, measure voltage
from B+ lead to ground using a DC voltmeter.
Condition
Voltage is 14.7 volts or
less.
Voltage is more than 14.7
volts.
Electrical System
Conclusion
Charging system is OK.
Battery is unable to hold
charge; service or replace.
Faulty rectifier-regulator;
replace.
47