Kenwood TK-3212L Service Manual page 21

Table of Contents

Advertisement

Item
Condition
5.Low power TEST CH: Low'
Check
High'
BATT terminal voltage:7.5V
PTT:ON
6.VOX 1
TEST CH: Center
Writing
AG:1kHz/45mV
7.DQT
TEST CH: Center
balance Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
8.Max deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
AG:1kHz/110mV
Deviation meter filter
LPF:15kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
9.QT deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH: Center
PTT:ON
10.DQT deviation TEST CH: Center
Adjust
Low
[Wide]
High
(3 points)
LPF:3kHz
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
11.DTMF deviation TEST CH:Center
Adjust
LPF:15kHz
[Wide]
HPF:OFF
PTT:ON
[Narrow]
TEST CH:Center
PTT:ON
ADJUSTMENT
Measurement
Test equipment
Terminal
Power meter
ANT
Ammeter
Power meter
ANT
Deviation meter
SP/MIC connector
Oscilloscope
ANT
AG
AF VTVM
ANT
SP/MIC connector
ANT
TK-3212L
Adjustment
Parts
Method
Check
Programming
Software:KPG-100D
Programming
Make the
Software:KPG-100D demodulation
wave into
square waves.
Programming
4.2kHz
Software:KPG-100D (According to
the larger +,–)
2.2kHz
(According to
the larger +,–)
Programming
0.80kHz
Software:KPG-100D
0.42kHz
0.75kHz
0.38kHz
3.0kHz
1.5kHz
Specifications/
Remarks
0.85~1.1W
1.0 A or less
±80Hz
±80Hz
±40Hz
±40Hz
±40Hz
±40Hz
±100Hz
±100Hz
21