PLUS ONE
5. The disc table rotates in the clockwise direction. The disc table rotation time is displayed with ''PLUS ONE" slit as a measuring point.
6. Measure the waveform of the oscilloscope when the disc table is rotating.
7. Move the holder (sensor) center so that the flat portion center at the top of the D.SENS (CH1) input waveform and the ''H" center of
HHOUT (CH2) coincide.
TE
L 13942296513
Holder (sensor)
8. Tighten the fixed screw to fix the disc table, then press the CLEAR button.
9. The disc table rotates in the counterclockwise direction. Measure the waveform and make sure that the flat portion center at the top of the
D.SENS (CH1) input waveform and the ''H" center of HHOUT (CH2) coincide.
10. If the adjustment is not successful, press the CLEAR button to rotate the disc table in the clockwise direction, and perform steps 6 to 9.
Note: During the adjustment mode, the rotational direction is switched each time the CLEAR button is pressed.
Pressing the CHECK button enters the loading mode which will be described later. Pressing the CLEAR button rotates the disc table
again.
www
.
http://www.xiaoyu163.com
HHOUT (CH2) waveform
D.SENS (CH1) waveform
Fixed screw
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Q Q
3
6 7
1 3
1 5
co
.
— 19 —
9 4
2 8
Flat portion center of
D.SENS (CH1) waveform
0 5
8
2 9
9 4
2 8
m
9 9
9 9