9. As the tank water temperature reaches
its target temperature, the heating
elements
will
succession.
5.6 THERMOSTATICALLY CONTROLLED
MIXING VALVE SETTING
A
thermostatically
automatically regulates the mix of very hot and
cold water as required, providing safe domestic
hot water under variable conditions.
To adjust the mixing valve setting, carefully open
a hot water tap. Protect yourself against the
scalding. Measure the hot water temperature
with a thermometer. Mixing valve adjustment is
achieved by turning the mixing valve knob
COMBOMAX™ Installation, use and care manual
be
turned
off
controlled
mixing
valve
clockwise
temperature,
domestic water temperature
in
Unless local regulation requires otherwise, a
50°C (120°F) is considered the best temperature
to reduce heat loss through the plumbing and
prevent scalding for young kid and senior
citizen. Generally residential dishwasher are
provided with their own water heating element
and don't required hotter water.
Raising
the
temperature will not provide more domestic hot
water. In order to provide more domestic hot
water, the amount of energy in the water heater
tank need to be increase, this is achieved by
increasing
(maximum 88°C /190°).
,
(Revision Sept. 2013)
to
reduce
the
domestic
contraclockwise
to
domestic
hot
the
water
tank
Page
water
raise
the
water
outlet
temperature
17.