Electric boiler with integrated instantaneous water heater
capacity from 8 kw to 24 kw :
240 volts ( single phase )
with installation instructions for the contractor (25 pages)
Summary of Contents for COMBOMAX ULTRA 12-4.5
Page 1
20 8/ 2 4 0 V o lt s ( sing le ph as e ) INSTALLATION, USE AND CARE MANUAL ® Your COMBOMAX electric boiler has been carefully assembled and factory tested to provide years of trouble-free service. This manual contains instructions for the safe and...
Page 2
Fresh water inlet : 3/4"NPT F Domestic hot water outlet : 3/4"NPT F Expansion tank : 1/2"NPT M Heating, supply : 1’’ NPT F Heating return : 1’’ NPT F COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
• Tank and domestic hot water heat 2.1 LOCAL INSTALLATION exchanger drain cocks. REGULATIONS • Thermo manometer (heat This COMBOMAX™ Ultra 12 electric boiler must pressure indicator). installed accordance with these • Automatic air vent. instructions must...
NSF International recommendations. operating pressure to 207 kPa (30 psi). The room temperature must be maintained This COMBOMAX™Ultra 12 electric boiler is between 10C (50F) and 33°C (90°F). designed for a maximum operating temperature of 88°C (190°F). It is designed for hot water 3.3 CLEARANCE...
Page 5
Figure 1 : Top view, components identification and their location Figure 2 : Front view, components identification and their location : COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
Page 6
Figure 3 : Basic installation diagram for a radiant floor heating system. Figure 4 : Basic installation diagram for a radiator installation COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
It will also maintain a minimal operating pressure cold pressure of 83 kPa (12 psi). When 3.5 HEATING WATER CIRCUIT operating the COMBOMAX™ Ultra 12 and the heating system, pressure will vary between 83 kPa and 193 kPa (12 psi to 28 psi). The 3.5.1 Connecting...
This excessive operation COMBOMAX™ Ultra 12 must be a 120/240 Vac, can cause premature failure of the relief valve single phase, 60 Hz using 3 conductors (L1 – and possibly of the water heater itself.
Page 9
The components must wired such that, upon a heating demand from a thermostat, only the corresponding zone valve will be actuated and will in turn activate the COMBOMAX™ Ultra 12 . Connect the zone valve dry end switch contact to the W and R boiler electrical panel terminals.
Page 10
Bleu 3 Set D Bi-E 2 Ht D 14 Pmp Demande Chauffage thermostat/ Bleu 13 Pmp 1 CD Heat Demand thermostat Noir/blk Rouge/Red Bleu Sonde temp. chaudière/ Boiler temp. Sensor COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
Page 11
COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
Section 4 : ( ™) CONTROL SET UP 4.1 INTRODUCTION The COMBOMAX™ Ultra 12 boiler is designed to be heating element(s). It is also capable of directly used in hydronic heating application where the managing one heating system circulating pump.
When the tank properly set-up the COMBOMAX™ Ultra 12 for the temperature decrease under the target temperature, application in order to maximise its performances.
“0” to be displayed. This zero indicates that the “user” differential value is zero. By using the “+” or “-“ keys, the user can input a temperature differential between the installer set point and the actual operation set COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
There is a hot water scald potential if the thermostatically controlled mixing valve for reducing point-of-use water temperature is damaged, not properly working removed or by-passed. COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
(water) and the domestic hot water. This heat required according power exchanger containing potable water must be capacity of the Combomax and the type filled. of heating system to reach the tank Make sure that the heat exchanger drain cock is water temperature target.
Page 17
Measure the hot water temperature increasing water tank temperature with a thermometer. Mixing valve adjustment is (maximum 88°C /190°). achieved by turning the mixing valve knob COMBOMAX™ Installation, use and care manual Page (Revision Sept. 2013)
Check for proper operation of the boiler controller, circulating pump(s), mixing valve for low temperature heating system, room thermostat(s) other heating system components for proper operation. Chaudière électrique COMBOMAX Guide d’installation, d’utilisation et d’entretien , Page (Révision Sept.2013)
Page 19
(1) accumulate in the COMBOMAX tank and boiler water acidity is lower than pH COMBOMAX ™ Ultra 12 tank and exchanger is to be use in only one (1) dwelling. 6.5 or higher than pH 8.5; or In the event that a leak should develop and occur within this limited warranty period The COMBOMAX unit is being subject to non authorized modifications;...
Need help?