CHART FOR MINIMUM WIRE SIZE OF EXTENSION CORD:
Nameplate AMPS
0-6
6-10
10-12
12-16
If in doubt, use larger cord.
Be sure to check voltage requirements of the tool to your incoming power source.
· Do not expose compressor to rain or wet conditions. Water entering a motor will increase
the risk of electric shock.
· Do not let your fingers touch the terminals of plug when installing to or removing from the
outlet.
· Ground fault circuit interrupters. If work area is not equipped with a permanently
installed Ground Fault Circuit Interrupter outlet (GFCI), use a plug-in GFCI between
compressor or extension cord and power receptacle.

PERSONAL SAFETY

· Stay alert, watch what you are doing and use common sense when operating a
compressor. Do not use a compressor while you are tired or under the influence of drugs,
alcohol or medication. A moment of inattention while operating a compressor may result in
serious personal injury.
· Dress properly. Do not wear loose clothing, dangling objects, or jewelry. Keep your hair,
clothing and gloves away from moving parts. Loose clothes, jewelry or long hair can be
caught in moving parts. Air vents often cover moving parts and should be avoided.
· Use safety apparel and equipment. Use ANSI-approved safety goggles or safety glasses
with side shields which comply with current national standards, or when needed, a face
shield. Use as dust mask in dusty work conditions. This applies to all persons in the work
area. Also use non-skid safety shoes, hardhat, gloves, dust collection systems, and hearing
protection when appropriate.
· Avoid accidental starting. Ensure the switch is in the off position before plugging tool
into power outlet. In the event of a power failure, while a compressor is being used, turn the
switch off to prevent surprise starting when power is restored.
· Do not overreach. Keep proper footing and balance at all times.
· Remove adjusting keys or wrenches before connecting to the power supply or turning
on the tool. A wrench or key that is left attached to a rotating part of the tool may result in
personal injury.
TOOL USE AND CARE
· Never use a compressor with a malfunctioning switch. Any compressor that cannot be
controlled with the switch is dangerous and must be repaired by an authorized service
representative before using.
· Disconnect power from compressor and place the switch in the locked or off position
before servicing, adjusting, installing accessories or attachments, or storing. Such
preventive safety measures reduce the risk of starting the compressor accidentally.
· Secure work with clamps or a vise instead of your hand to hold work when practical. This
safety precaution allows for proper tool operation using both hands.
· Store idle compressor. When a compressor is not in use, store them in a dry, secure
place out of the reach of children. Inspect the compressor for good working condition prior
to storage and before re-use.
· Use only accessories that are recommended by the manufacturer for your model.
Accessories that may be suitable for one compressor may create a risk of injury when used
on another compressor.
· Never leave compressor running unattended.
25'
50'
18 AWG
16 AWG
18 AWG
16 AWG
16 AWG
16 AWG
14 AWG
12 AWG
3 OF 5
CORD LENGTH
100'
16 AWG
14 AWG
14 AWG
(NOT RECOMMENDED)
150'
14 AWG
12 AWG
12 AWG

Advertisement