WEGJ 2000 (SUB1.0) – TYPICAL INSTALLATION
FIG A
WEGJ 2000 (Sub 1.0) Flue Mounted Shield (Flue Guard) Kit.
Complies (with heater) to AS/NZS 2918:2001
TOP CAP (Fits inside flue)
5mm Max
LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM
FLASHING
25 MM BETWEEN LINER
AND ANY TIMBER.
TIMBER RAILS
SUPPORT ANGLES
25 mm min BETWEEN LINER
& ANY TIMBER
LINER POSITIONED BY SPIDER
BRACKETS TOP & BOTTOM.
SUPPORT ANGLES
300mm sq TIMBER FRAME
CEILING
1200mm LINED
BACK GUARD
TERTIARY
BACK GUARD
TWO SEISMIC RESTRAINT
attachment points.
cover with caps.
100
Note: All Dimensions are in millimetres.
FIG.C: WEGJ 2000 HEATER DIMENSIONS AND WATER BOOSTER POSITIONS
Wegj 2000 Installation Instructions - AUG_2014.doc
FLUE
50
Top Front
Angled
Deflector
1200mm FRONT GUARD
ASH FLOOR
PROTECTOR
535
300
(drawings on the following pages are not to scale)
COWL MUST SIT HARD DOWN ON BRACKETS ON TOP OF LINER
TO PREVENT WIND NOISE AND RAIN PENETRATION.
ENLARGEMENT OF CEI LI NG ASSEMBLY
FIG B
2 5 m m m in . BETWEEN LI NER & ANY TI MBER
LINER POSITIONED BY SPIDER
BRACKETS. TOP/BOTTOM
SUPPORT ANGLES
TIMBER RAILS
INSULATION BOUNDARY SHIELD
CEI LI NG
CUT CEI LI NG MATERI AL
BACK 2 5 m m CLEAR
OF BOUNDARY SHEI LD.
3 0 0 m m Sq. TI MBER FRAME
CONDITIONS FOR FLUES (Refer Fig. E)
The FLUE shall extend to:
1.
Not less than 600mm above the highest point on
the roof if within 3.0m of that point, or
Not less than 1000mm above the
intersection point with the roof and not lower
than any point of the roof within 3.0m.
In any case the length of the flue shall not be
less than 4.6m from the ash floor protector.
In some situations the Local Council may
vary the above requirements.
2.
The flue system must be tested and comply
with AS/NZS2918:2001, Appendix F.
3.
The insulation boundary shield shall be
capable of preventing accidental migration of
loose-fill or any combustible material by any
action of wind or by persons moving in the
ceiling space.
These instructions, spare parts information,
operation and maintenance guides may be
downloaded from www.yunca.co.nz
www.yunca.co.nz
CEI LI NG PLATE
2 5
FIG B
(not to scale)
Page 2 of 4