maintenance

Maintenance Schedule

Make sure the engine is stopped before starting any maintenance,
servicing or repair.
NOTE: It is recommended to use ear protection when performing
operation, maintenance and repair of the generator.
Maintenance, replacement or repair of the emission control devices
and systems must be performed by an authorized service provider.

Daily Inspection

Before running the generator, check the following service items:
• Safe surroundings.
• Leakage of gasoline and engine oil.
• Clean engine oil.
• AC receptacle and DC terminal for damage.
• Enough gasoline.
• Excessive vibration, noise.
• Loose or broken bolts, nuts or shields.
• Clean air element.

Periodic Maintenance

Periodic maintenance is vital to safe and efficient operation of your
generator.
The emission control system consists of the following parts:
• Carburetor and internal parts
• Cold start enrichment system, if applicable
• Intake manifold, if applicable
• Air cleaner element
• Spark plug
• Magneto or electronic ignition system
• Exhaust manifold
• Hoses, connectors, and assemblies

Changing Engine Oil

Change oil after the first 20 hours of operation. Thereafter it should be
changed every 100 hours. This generator uses SAE 10W30 oil.
1. Drain oil by removing the drain plug and the oil filler cap while the
engine is warm.
2. Reinstall the drain plug and fill the engine with oil until it reaches
the upper level on the oil filler cap.
28