NATURAL GAS CONNECTIONS

Pipe sealing compound or pipe thread tape of the type resistant to the
action of natural gas must be used on all male pipe thread. Apply compound
or tape to at least the first three threads when making the connection.
Remove plastic cap from regulator installed on grill.
Attach outdoor flex line ½ " for main burner supply or 3/8" for
side burner to the regulator.
Attached the other end of flex line to shut-off valve thru a
nipple. Attach a shut-off valve to gas supply pipe.
PERFORM GAS LEAK CHECK -SEE PAGE 2

PROPANE GAS CONNECTIONS

The LP gas pressure regulator and hose assembly supplied with this unit
must be used without alteration. If this assembly needs to be replaced,
use only the type 1 specified in the parts list supplied with this unit.
Use a LP tank with a type 1 cylinder valve. Make sure the tank is firmly
secured in an upright position.
Turn the black coupling nut of the hose and regulator assembly in a
clockwise direction. Make sure it is completely threaded onto the cylinder
valve before turning gas supply on.
PERFORM GAS LEAK CHECK — SEE PAGE 2
LP Gas regulator assembly hose should be
At least 20" long.
Connector must comply with the standard for connectors for outdoor gas appliances
and manufactured homes, ANSI Z21.75/CSA 6.27.