If grill fails to operate properly
1. Turn off gas at source, turn control knobs to "OFF",
and wait five minutes before trying again
2. Check gas supply/connections.
3. Repeat lighting procedure and, if grill still fails to operate properly,
TURN "OFF" GAS AT SOURCE, TURN CONTROL KNOBS TO "OFF",
wait for grill to cool, and check the following:
a. Misalignment of burner tube(s) over orifice(s)
CORRECTION: Reposition burner tube to properly seat over orifice.
b. Obstruction in gas line
CORRECTION: Remove fuel line from grill. DO NOT SMOKEI Open gas supply for one second to blow any obstruction from
line. Close off gas supply at source and reconnect fuel line to grill.
c. Plugged orifice
CORRECTION: Remove cooking grids, flame tamers, grease draining tray. Remove burners from bottom of grill bowl by pulling cotter
pin from beneath burner peg using a screwdriver or needle nose pliers. Carefully lift each burner up and away from gas valve orifice.
Remove the orifice from each burner up and away from gas valve and gently clear any obstruction with a fine wire. Re-install each
orifice, reinstall burners over orifices and seat each burner peg into mounting bracket at bottom of grill bowl. Replace cotter pins.
Replace cooking components and grease collectors. If an obstruction is suspected in gas valve(s) or gas valve bracket, please contact
your gas grill dealer or gas appliance service person for assistance.
d. Misalignment of igniter on burner
CORRECTION: Check for proper position of electrode tip. The tip of the electrode should be pointing forward toward the front and free
from grease for spark discharging. The ignition wire should be connected to the valve ignition and electrode firmly. Replace the ignition
wire if the wire were broken or cracked. With gas supply closed and all control knobs set to "OFF", check each positive igniter
individually for presence of spark at electrode. In turn, push each control knob in fully and rotate about 1/4 turn to the left (counter-
clockwise) until click is heard; the trigger hitting the strike block should produce a blue spark at the electrode tip. Return control knob
to "OFF" before checking next igniter. If re-ignition is necessary.

TROUBLESHOOTING