(diagram 11)
7. Dormancy
Under normal working condition, when the user put the handle on the bracket,
then the equipment will be automatically switch to the dormancy condition and
the heater also stops heating. This happens in the case when the temperature is
higher than 100 , during the hot-air station dormancy period the screen A
display character SLP (diagram 3)
Screen A: Standby
(diagram 3)
8.Conversation between cold-air and hot-air
In normal condition, continually press " "knob twice and then make the
hot-air be in the state of cold-air blow (diagram12). Under the cold-air
condition, press "
" knob once, recover the hot-air working condition.
9.Standby
Under normal working condition, the device keep the current temperature and
air volume and cut down heating to the rework station after pressing POWER
knob at the left of panel (diagram 1A), below 100 , the device is standby
(diagram1). If power is off, the soldering station is off, whole device will be off
after the temperature below 100 .
(diagram 1A)
(diagram 12)
Standby state of screen A
(diagram 1)
11
10. Error/Fault indication
1. When "H-E" is displayed on the screen A, there is no hot air in the nozzle
(diagram13), which indicates that the heating element fails.
2. When "S-E" is displayed on the screen A, there is a fault in sensor
(diagram14), which signifies that there is something wrong with the
sensor or the related circuit of the sensor.
Screen A: no hot-air fault
(diagram 13)
II. SOLDERING STATION
1.Power on
Screen B which displays actual temperature in 3s displays setting temperature
after pressing POWER knob at the right of panel (diagram15, diagram16).
Screen B:
Temperature Settings
(diagram 15)

2.Temperature setting

In normal working condition, if screen B shines
press SET knob twice to switch to shine
to adjust temperature. Screen B shines"SET" and the main temperature area
shines the setting temperature of soldering station. Stopping pressing knob or
pressing SET knob confirm and keep settings and quit from this operation
(diagram17).
Screen A: sensor fault
(diagram 14)
Screen B: heating
(diagram 16)
or you at first continually
, then press the UP or DOWN knob
12