Restart Function; Troubleshooting - Rinnai ES38 RHFE-1004RFA Owner's Operation And Installation Manual

Hide thumbs Also See for ES38 RHFE-1004RFA:
Table of Contents

Advertisement

Available languages

Available languages

Restart Function

If the appliance fails to ignite, the appliance will attempt ignition after 1 hour. The "Ignition Failure" fault code, 11,
will appear during that hour and disappears after a successful ignition. If ignition fails again, then the fault code
will remain and another attempt to ignite will occur in 1 hour. The fault code is not stored in the fault code history.
If the flame is extinguished during forced combustion then the appliance will attempt ignition after 1 hour. The
"Ignition Failure" fault code, 11, will appear during that hour and disappears after a successful ignition. Forced
combustion takes place for about 15 seconds after ignition. After this time, the temperature control logic controls
the combustion.
If the flame is extinguished (burner combustion failure) while the temperature control logic is operating the
appliance, then the appliance will immediately attempt ignition. No fault code will appear.

Troubleshooting

Problem
Cause
Not Plugged In
Power Failure
(Initial Installation)
Air In Gas Pipe
Gas Filter Blocked
Miss Ignition
Flue terminal obstructed
Flue manifold not connected
Louver obstructed
Air filter blocked
Gas Escape
Function Lock Set
Gas turned off at meter, tank,
or valve.
Rinnai Corporation ES38 Manual
Remedy
Plug In
Push On/Off button to attempt
restart after power is restored.
Purge air
(Installer)
Service Call
Service Call
Clear obstruction
Service Call
Clear obstruction
Clean filter
Service Call
Cancel Function Lock
Turn gas on
13

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Es38

Table of Contents