Toshiba RAS-24UAH-E-1 Service Manual page 6

Table of Contents

Advertisement

Note : 1
• Capacity is based on the following temperature conditions.
Temperature
Indoor unit inlet air temperature
Outdoor unit inlet air temperature
Note : 2
• Charge refrigerant according to the table below.
Refrigerant
*1
No need to charge
extra refrigerant
*2
Need to charge
extra refrigerant
Condition
(DB)
(WB)
(DB)
(WB)
RAS-24UKHP-E-1 / RAS-24UAH-E-1
RAS-24UKP-AR-1 / RAS-24UA-AR-1
15 m or less
Over 15 m up to 25 m (20 g/m)
- 5 -
FILE NO. SVM-03010(1)
JIS C9612-1994
Cooling
27°C
19°C
35°C
24°C
RAS-18UKHP-E2 / RAS-18UAH-E2
RAS-18UKP-AR2 / RAS-18UA-AR2
RAS-18UKPX-T2 / RAS-18UAX2-T2
15 m or less
Over 15 m up to 20 m (20 g/m)
Heating
20°C
12°C
7°C
6°C