Call Forwarding Feature
The call forwarding feature will allow a visitor to contact the resident at
the programmed telephone number instead of through the local telephone
line. The feature can be set to be active during a selected Time Zone or
at all times. The telephone number programmed can contain an extension
number and an optional time delay before dialing the extension.
Press:
Telephone Number
Forwarding: 0 = Call forwarding feature OFF
1 = Call forwarding feature ON at all times
2 = Call forwarding feature ON (scheduled by Time Zone)
3 = Forward the call if there was no resident answer
Time Zone = 1-7 (Call forwarding feature active during this Time Zone)
Telephone Number = Up to 11-digit telephone number
Extension = Up to 4-digit telephone extension number
Delay = 1-25 seconds (delay between telephone number and extension)
Example, call forwarding with only a phone number:
Press:
A special feature is implemented for "Ring Down" PBX systems. If no
telephone number is programmed and call forwarding is enabled, the unit
will connect immediately without dialing.
Alternate Resident Telephone Numbers
For installations where multiple residences exist behind shared controlled
access, the RE-2 can dial three alternate telephone numbers. The visitor can
call an alternate number by entering "1#", "2#", or "3#" on the main keypad.
Press:
Telephone Number
Location: 1 = "1#" location; 2 = "2#" location; 3 = "3#" location
Enable: 0 = Disable; 1 = Unconditionally enable
Telephone Number: Up to 11-digit telephone number
Extension: Up to 4-digit telephone extension number
Delay: 1-25 seconds (delay between telephone number and extension)
Resident Response Telephone Keys
Key D "6" = Switch To/From Call Waiting
The resident response keys are the telephone keys that the resident uses to
grant access and control calls from a visitor. The keys for the four functions
can be customized. Enter all four keys each time this programming PPN is
used.
Press:
Keys ABCD: Enter 4 digits for the response keys A, B, C, & D
Key A = Activates Relay #1
Key B = Activates Relay #2
Key C = Disconnects the Visitor's Call
Key D = Switches to and from a call holding on call waiting
Resident Programming and Command Prefi xes
The resident command prefi x is entered on a local telephone prior to
entering a command number to control one of the relays or open voice
communications with the RE-2. The resident programming prefi x is entered
on a local telephone or the main keypad prior to programming the RE-2.
Press:
Programming
Programming: 0 = "###"; 1 = "***"; 2 = "*#*"; 3 = "#*#"
Command: 0 = "##"; 1 = "**"; 2 = "*#"; 3 = "#*"
18
Default: OFF
Forwarding
Time Zone
Extension
Delay
Telephone Number
Default: All Disabled
Location
Enable
Extension
Delay
Key A "1" = Activates Relay #1
Key B "2" = Activates Relay #2
Key C "9" = Disconnect Visitor's Call
Keys ABCD
Programming = "###"
Command = "##"
Command

ADVANCED SYSTEM PROGRAMMING

Reset System Defaults
The system can be reset back to the factory defaults with this programming
PPN. EXECUTING THIS PPN WILL NOT ERASE ANY ENTRY CODES OR
TRANSMITTERS THAT HAVE BEEN PROGRAMMED.
Relay #1 On Time
Changes the length of time Relay #1 activates when triggered.
Relay #2 On Time
Changes the length of time Relay #2 activates when triggered.
Main & Remote Keypad Relay and Time Zone
Sets the relay and time zone that the main and remote keypad will use.
Press:
Keypad: 1 = Main Keypad
2 = Remote Keypad
(Also see PPN #28)
Relay: 1 = Relay #1
2 = Relay #2
3 = Set by entry code
Time Zone: 0 = no time zone
1-7 to restrict access per time zone 1-7
✦ NOTE: To have an entry code select which relay activates, the relay
option should be set to "3".
Relay #2 Alternate Options
Relay #2 can be used for functions other than triggering a gate operator
or door strike. Relay #2 can be programmed to shunt alarm contacts
during Relay #1 activation or perform up to fi ve Alarm Functions. Two PPN
Defaults:
numbers are used to program the Relay #2 options.
Role: 0 = Access Relay
1 = Alarm Shunt (Follows Relay #1 activation, used to shunt
2 = Obstacle Detector
3 = Activate during one or more of the fi ve Alarm
✦ NOTE: More than one alarm function can be enabled at a time. Up to fi ve
digits can be entered for "Activate".
Activate: 0 = No alarm function (default)
1 = On forced entry (activates when SENSE #1 input opens
2 = On door/gate ajar (activates when SENSE #1 input stays
Defaults:
3 = On main keypad lockout (activates when the main keypad
4 = On remote keypad lockout (activates when the remote
5 = On driveway sensor (activates when SENSE #2 input closes)
Press:
Press:
Time
Seconds = Output time in seconds 0-60
Press:
Time
Seconds = Output time in seconds 0-60
Default: Main Keypad = Relay #1, No Time Zone
Remote Keypad = Disabled
Keypad
Relay
Press:
Role
external alarm contacts with Relay #2's contacts)
Functions programmed below
Press:
Activate
without Relay #1 activation)
open for longer than one minute after Relay #1 activation)
is in "lockout" from too many incorrect code attempts)
keypad is in "lockout" from too many incorrect code
attempts)
Default 2: Seconds
Default: 2 Seconds
Time Zone
Default: Access Relay