Toshiba RAS-13UKHP-ES3 Service Manual page 71

Hide thumbs Also See for RAS-13UKHP-ES3:
Table of Contents

Advertisement

No.
Part name
2
Capacitor for
compressor
3
Capacitor for
fan motor
Procedures
1) Perform the common procedure
2) Remove the fixing screw and the capacitor
band.
(1-Screw ∅4 x 8L for 10k, 13k)
(1-Screw ∅4 x 10L for 07k)
3) Disconnect the lead wires.
1) Perform the common procedure
2) Remove the fixing screw
(1-Screw ∅4 x 10L)
3) Disconnect the lead wires.
1
.
1
.
− 70 −
FILE NO. SVM-04001
Remarks
Screws
∅4 x 8L
Capacitor band
Capacitor for fan motor
RAS-10K, 13K
Screws ∅4 x 10L
RAS-07K
Capacitor
for
compressor
Screws
Ø4 x10L
Capacitor for
Compressor
Capacitor
band
Capacitor for
fan motor
Screws
∅4 x10L