S I E M E N S P T E L T D
M65 Level 2 Service Manual
Step 5
Remove the Battery as shown.
Step 7
Unscrew the 4screws (as indicated) on the Lower Case
with a T5 Plus screw driver (set Torque = 16 cNm).
Step 9
Separate the Lower Case from the Upper Case.
Copyright © Siemens Pte Ltd.
All Rights Reserved
ICM MP CCQ SLI RHQ
Step 6
Remove the SIM card in the direction as shown.
Step 8
Unscrew the 2 screws (as indicated) on the Upper Case
with a T5 Plus screw driver (set Torque = 16 cNm).
Step 10
Remove the Vibra Motor, Micro R65 and Sealing Plug
from the Lower Case.