Summary of Contents for Jun-Air 86

  • Page 1 Compressor Model 86/87R System 86R-4B, 87R-4B, 87R-15B, 87R-25B ISO 9001 CERTIFIED JUN-AIR® is a registered trademark of Gast Manufacturing, Inc. and Gast Group Ltd. ©Copyright 2015 Gast Manufacturing, Inc. All rights reserved.
  • Page 2 6190755 (Rev A) 86/87R Compressor System User Guide Table Of Contents Section Page Number Declaration of Conformity Operating Manual Diagrams / Schematics Exploded Views Parts and Accessories Technical Data & Specifications Pictures & Illustrations © 2015, JUN-AIR We reserve the right to make any alterations which may be due to any technical improvements...
  • Page 3: Declaration Of Conformity

    6190755 (Rev A) 86/87R Compressor System User Guide Declaration of Conformity Konformitätsbescheinigung Certifi cat de Conformité Declaración de Conformidad Conformiteitsverklaring Overensstemmelseserklæring Th e manufacturer Gast Manufacturing, Inc. declares that the compressor is in conformity with: • 2009/105/EC Council Directive relating to Simple Pressure Vessels •...
  • Page 4: Operating Manual

    Do not operate system at ambient temperatures exceeding 40°C/104°F or falling below 5°C/41°F. • If the supply lead on the system is defective, an authorized JUN-AIR distributor or Important - read this first! other qualified personnel must carry out the repair.
  • Page 5: Electrical Installation

    If maximum pressure is exceeded, reduced lifetime may result. in a dustfree, dry and cool, yet frostfree, room. Do not install in a closed Contact JUN-AIR for information on operation at higher cupboard, unless adequate openings for ventilation are available on top pressure.
  • Page 6: Preventive Maintenance

    Test the safety valve by gently pulling the ring with pressure in the receiver. Filters and non-return valves should be serviced every 2000 hours. The JUN-AIR basic service kit (identified in the accessories portion of this manual) can be purchased to accommodate.
  • Page 7 6190755 (Rev A) 86/87R Compressor System User Guide Pressure vessel 16.5 - 24BAR Pressure tested at: All sizes: Directions for use Application Receiver for compressed air. Receiver specifications See name plate. Installation Tubes, etc. must be installed with suitable materials.
  • Page 8 6190755 (Rev A) 86/87R Compressor System User Guide 86/87R- XB Wiring Schematics 120VAC - 60Hz 30 μF CAPACITOR Legend 30 μF CAPACITOR : AUTO DRAIN : FAN :CAPACITOR :EARTH :TERMINAL CLIP :MOTOR PROTECTION :ADDITIONAL FEATURES NEW DRAWING ----- REV. DESCRIPTION REVISIONS ©...
  • Page 9 6190755 (Rev A) 86/87R Compressor System User Guide 86/87R- XB Wiring Schematics 120VAC / 230VAC - 50Hz or 60Hz 30 μF CAPACITOR Legend 30 μF CAPACITOR : AUTO DRAIN : FAN :CAPACITOR :EARTH :TERMINAL CLIP :MOTOR PROTECTION :ADDITIONAL FEATURES NEW DRAWING ----- REV.
  • Page 10 6190755 (Rev A) 86/87R Compressor System User Guide 86/87R- XB Pneumatic Schematic Legend :WORKING PIPE :STEERING PIPE :PIPE COUPLING :COMPRESSOR :TANK :INLET FILTER :PRESSURE GAUGE :PRESSURE SWITCH :SAFETY VALVE :NON RETURN VALVE :FILTER MANUAL DRAIN :VALVE FOR PRESSURE RELIEF :REDUCTION VALVE...
  • Page 11: Exploded Views

    1760420 - EXPLODED 6190755 (Rev A) 86/87R Compressor System User Guide SHEET 1 OF 1 86/87R- XB Exploded Views 2/20/2015 86R-4B 230V/50Hz CE 1760420 DATE DESCRIPTION PART NUMBER 86R-4B 230V - 50Hz REFERENCE ONLY 5031000 7190000 6341101 6973090 7071000 6973105...
  • Page 12 6190755 (Rev A) 86/87R Compressor System User Guide 1760421 - EXPLODED SHEET 1 OF 1 86/87R- XB Exploded Views 2/20/2015 1760421 86R-4B 230V/60Hz UL DATE DESCRIPTION PART NUMBER 86R-4B 120V/230V - 60Hz REFERENCE ONLY 6294600 6293100 6293100 5075000 6294600 7190000...
  • Page 13 1760400 - EXPLODED SHEET 1 OF 1 6190755 (Rev A) 86/87R Compressor System User Guide 2/20/2015 87R-4B 230V/50Hz CE 1760400 86/87R- XB Exploded Views DATE DESCRIPTION PART NUMBER 87R-4B 230V - 50Hz REFERENCE ONLY 5031000 7190000 6341101 6973090 7071000 6973105...
  • Page 14 1760401 - EXPLODED SHEET 1 OF 1 6190755 (Rev A) 86/87R Compressor System User Guide 2/20/2015 1760401 87R-4B 230V/60Hz UL 86/87R- XB Exploded Views DATE DESCRIPTION PART NUMBER 87R-4B 120V/230V - 60Hz REFERENCE ONLY 6294600 6293100 6293100 5075000 6294600 7190000...
  • Page 15 6190755 (Rev A) 86/87R Compressor System User Guide 1760430 - EXPLODED SHEET 1 OF 1 86/87R- XB Exploded Views 2/12/2015 87R-15B 230V/50Hz CE 1760430 DATE DESCRIPTION PART NUMBER 87R-15B 230V - 50Hz REFERENCE ONLY 6290200 5340000 6296850 5935012 7024002 6392145...
  • Page 16 1760431 - EXPLODED SHEET 1 OF 1 6190755 (Rev A) 86/87R Compressor System User Guide 2/12/2015 87R-15B 230V/60Hz UL 1760431 86/87R- XB Exploded Views DATE DESCRIPTION PART NUMBER 87R-15B 120V/230V - 60Hz REFERENCE ONLY 6290200 5340000 6296850 5935012 6392145 7024002...
  • Page 17 6190755 (Rev A) 86/87R Compressor System User Guide 1760410 - EXPLODED SHEET 1 OF 1 86/87R- XB Exploded Views 2/12/2015 87R-25B 230V/50Hz CE 1760410 DATE DESCRIPTION PART NUMBER 87R-25B 230V - 50Hz REFERENCE ONLY 6290200 5340000 6296850 5935012 7024002 6392145...
  • Page 18 6190755 (Rev A) 86/87R Compressor System User Guide 1760411 - EXPLODED SHEET 1 OF 1 86/87R- XB Exploded Views 2/12/2015 87R-25B 230V/60Hz UL 1760411 DATE DESCRIPTION PART NUMBER 87R-25B 120V/230V - 60Hz REFERENCE ONLY 6290200 5340000 6296850 5935012 7024002 6392145...
  • Page 19: Parts And Accessories

    6190755 (Rev A) 86/87R Compressor System User Guide Parts & Accessories List Part no. Description 4071030 5 micron outlet filter/regulator with manual drain 4071055 .01 micron outlet filter with manual drain 4071065 FILTER 0.01UM W/AUTODRAIN 4071210 SPARE PARTS KIT F/5micron Filter...
  • Page 20 6190755 (Rev A) 86/87R Compressor System User Guide Part no. Description Part no. Description 3050005 TANK - 4L CE/UL w/inspection *6341101 SCREW F/UNLOADER VALVE M5X6 3051000 4L TANK CE *6341800 M6x10 SHCS 3210005 TANK - 15B CE *6346300 M8x20 FLAT HEAD ZINC PLATE 3210098 Tank –...
  • Page 21: Technical Data & Specifications

    The figures in the tables are based on the unit working in a clean environment at an ambient temperature of 20°C, relative humidity of 50% and operating at sea level. The performance of the product will be adversely effected at high altitudes. JUN-AIR reserves the right to make technical modifications to these units as needed.
  • Page 22 The figures in the tables are based on the unit working in a clean environment at an ambient temperature of 20°C, relative humidity of 50% and operating at sea level. The performance of the product will be adversely effected at high altitudes. JUN-AIR reserves the right to make technical modifications to these units as needed.
  • Page 23 6190755 (Rev A) 86/87R Compressor System User Guide 86R-4B-BXXXX English Performance 50 Hz 60 Hz Pressure (PSI) 86R-4B-BXXXX Metric Performance 50 Hz 60 Hz Pressure (BAR) © 2015, JUN-AIR We reserve the right to make any alterations which may be due to any technical improvements...
  • Page 24 6190755 (Rev A) 86/87R Compressor System User Guide 87R-XB-JXXXX English Performance 50 Hz 60 Hz Pressure (PSI) 87R-XB-JXXXX Metric Performance 50 Hz 60 Hz Pressure (BAR) © 2015, JUN-AIR We reserve the right to make any alterations which may be due to any technical improvements...
  • Page 25: Compressor Configuration

    6190755 (Rev A) 86/87R Compressor System User Guide Tank Regulatory Elec/region config Accessory configuration Compressor Configuration Dryer Type Enclosure Style Receiver Size Family & cylinders Family & cylinders Receiver Size Enclosure Style Dryer Type 86R = single cylinder & small bore (low flow)
  • Page 26: Pictures & Illustrations

    6190755 (Rev A) 86/87R Compressor System User Guide Pictures / Illustrations References Pressure Switch ’1’ on or ’0’ off Pressure Switch Adjustment Safety Valve Non-Return Valve Non-Return Valve Assembly ( A + B + C) © 2015, JUN-AIR We reserve the right to make any alterations which may be due to any technical improvements...
  • Page 27 JUN-AIR dealer with the product sale and service records. Should the dealer not be able to complete the repair, the dealer may contact JUN-AIR for disposition. The product’s model and serial number, the installation date and the JUN-AIR invoice number must be fur- nished.