Kenwood TK-190 Service Manual page 40

Hide thumbs Also See for TK-190:
Table of Contents

Advertisement

TK-190
Item
Condition
14. Transmission 1) Set panel test mode
S/N check
CH No. : 3
Signalling No. : 1
Deviation meter filter setting
LPF : 300Hz
HPF : 3kHz
De-emphasis : 750µs
PTT : ON
15. BATT
1) Set panel test mode
detection
CH No. : 3
writing
Signalling No. : 1
Select BATT ∗ ∗ ∗
in panel tuning mode
PTT : ON
16. BATT
1) Set panel test mode
detection
CH No. : 3
check
Signalling No. : 1
BATT terminal voltage : 5.3V
PTT : ON
2) BATT terminal voltage : 6.5V
PTT : ON
Receiver Section
Item
Condition
1. AF level
1) Set panel test mode
check
CH No. : 3
Signalling No. : 1
SSG freq. : Each freq.
output : –53dBm/501µV
MOD. : 1kHz
DEV. : 2.4kHz
2. Hum and
1) Set panel test mode
noise ratio
CH No. : 3
check
Signalling No. : 1
SSG output : –53dBm/501µV
3. BPF coil
1) Set panel test mode
CH No. : 1
Use this
Connect the spectrum
adjustment
analyzer to TP3
procedure
Signalling No. : 1
after replace-
Push Monitor to 3 point
ing any of
adjustment mode
the BPF
Select SNS 75
coils
M
40
ADJUSTMENT
Measurement
Test-
Unit
Terminal
equipment
Power meter Panel
ANT
Deviation
meter
Oscilloscope
AG
Side
Universal
AF VTVM
Power meter Panel
ANT
Side
DC VTVM Bottom BATT
terminal
Measurement
Test-
Unit
Terminal
equipment
SSG
Panel
ANT
AF VTVM
Oscilloscope
Distortion
meter
Audio
analyzer
Tracking
Panel
ANT
TX-RX L201
generator
Spectrum TX-RX TP3
analyzer
Adjustment
Unit
Parts
Method
Check
Monitor Write the voltage
level
Check
Adjustment
Unit
Parts
Method
Check
Adjust the BPF coil so that the waveform is peaked.
L202
The frequency with the peak waveform does not
L206
have to be the center frequency.
After finished peaking the waveform, perform a
3 point adjustment and set for maximum sensitivity.
Specifications/Remarks
42dB or more
6.2V
Cannot transmit
LED (TX) blinks
Transmit
Specifications/Remarks
0.55V± 0.3V (VOL.2)
5% or less
42dB or more