Item
Condition
4. Low RSSI
[Analog Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[Analog Wide]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±3.0kHz
[NXDN Very Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[NXDN Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -120dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
5. High RSSI
[Analog Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[Analog WIde]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±3.0kHz
[NXDN Very Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
[NXDN Narrow]
1) Test CH : Low, Low', Center,
High', High ( 5 point )
2) SSG output : -80dBm
AF Freq : 1kHz
Mod Dev : ±1.5kHz
Measurement
Test-
Unit
Terminal
equipment
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
SSG
ANT
Oscilloscope
Audio
Analyzer
Adjustment
Unit
Parts
Method
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]
FPU Press [Start], [Auto
tuning]