Fiamma Elektra.6 BP-L HE Use And Maintenance Manual

Fiamma Elektra.6 BP-L HE Use And Maintenance Manual

Electric combi wall boiler for heating and sanitary hot water production instantaneous with accumulation tank
Table of Contents

Advertisement

ELECTRIC COMBI WALL BOILER
FOR HEATING AND SANITARY HOT WATER PRODUCTION
INSTANTANEOUS WITH ACCUMULATION TANK
Combi.
Elektra

USE AND MAINTENANCE MANUAL

EQUIPMENT COMPLIANT CE DIRECTIVE 2006/42 - IEC 60335-2-21:2012 with IEC 60335- 1:2010 with EN
60335-2-21:2003+A1:2005+A2:2008 - EN 60335-1:2012 - EN 62233:2008.
.. BP-L
series
HE
®

Advertisement

Table of Contents
loading

Summary of Contents for Fiamma Elektra.6 BP-L HE

  • Page 1: Use And Maintenance Manual

    ® ELECTRIC COMBI WALL BOILER FOR HEATING AND SANITARY HOT WATER PRODUCTION INSTANTANEOUS WITH ACCUMULATION TANK Combi. Elektra .. BP-L series USE AND MAINTENANCE MANUAL EQUIPMENT COMPLIANT CE DIRECTIVE 2006/42 - IEC 60335-2-21:2012 with IEC 60335- 1:2010 with EN 60335-2-21:2003+A1:2005+A2:2008 - EN 60335-1:2012 - EN 62233:2008.
  • Page 2 Company group The company FIAMMA GIRO s.r.l. declines all responsibility for possible inaccuracies contained in this pamphlet, if due to printing errors or inadvertent errors. However, reserves the right to make changes to its products that it deems useful or necessary, without...
  • Page 3 Dimensions The series Elektra... BP-L has four power levels, but the same overall dimensions: Elektra.6 BP-L 6 kW maximum electrical output Elektra.12 BP-L 12 kW maximum electrical output Elektra.18 BP-L 18 kW maximum electrical output Elektra.24 BP-L 24 kW maximum electrical output Packaging dimension Appliance dimension L (Width) :...
  • Page 4 Hydraulic connections – Dimensional of connection arrangement. Hydraulic connections Heating delivery : ¾” Heating return : ¾” Cold sanitary water inlet : ½” Hot sanitary water output: ½” VSR Heating safety valve (3 bar) : ½” VSS Sanitary safety valve (6,5 bar) : ½”...
  • Page 5 Main technical features Elektra 6.. - Elektra 12.. Elektra.6 BP-L HE 6 kW maximum electrical output Single-phase electrical supply 230 V - 50 Hz. Weight : 60 kg. Capacity of tank 37 lt. Glass-lined steel with inspection flange and magnesium anode.
  • Page 6 Main technical features of Elektra 18.. – Elektra 24.. Elektra.18 BP-L HE 18 kW maximum electrical output Single-phase electrical supply 230 V - 50 Hz. Weight : 62 kg. Capacity of tank 37 lt. Glass-lined steel with inspection flange and magnesium anode.
  • Page 7 Switching-on the boiler CONTROL PANEL General Display hydrometer switch Idrometro Idrometro The control panel is composed of : display, function selection keys, general switch hydrometer placed lower left corner in front of the unit (see image above). Using analogical hydrometer. The analogical hydrometer control panel has a dial with unit of measure in a bar, from 0 to 6 bar.
  • Page 8 KEYBOARD PANEL (Control panel) MEANING OF THE KEYS IN USER MODE FUNCTION Display / Tank setpoint decrease (only if JP8 = 0) Display / Tank setpoint increase (only if JP8 = 0) ON - OFF Switching Display temperature output / Display setpoint output Unlock error of safety thermostat Summer –...
  • Page 9 CHOICE OF THE OPERATION MODE (winter/summer) Pressing the key MODE (J4), it will be chosen the mode of operation, wintry or summery. Pressing repeatedly each time for at least 5 seconds, you switch from WINTER to SUMMER or from SUMMER to WINTER then. When the device will be in WINTER mode, on the display will appear the C C C C symbol...
  • Page 10 pressure alarm, the recovery will be automatic after that the hydric pressure will be restored at the minimum operating level (0,8 bar) by means of the opening and the closure of the charging tap placed under the boiler (black handle). The display has several symbols, signaling in addition to operation modes, also the various alarm or system displays: SYMBOL...
  • Page 11 INSTALLATION TECHNICAL NOTE FOR INSTALLER AND TECHNICAL MAINTENANCE HYDRAULIC SCHEME (Elektra 12 BP-L 015 HE version) Legend - TS Safety thermostat. - rs Filling tap. - VSS Safety valve for sanitary circuit 1/2”x6,5 bar. - PA Water pressure switch. - SP Brazed heat exchangers.
  • Page 13 MAIN ELECTRIC SCHEME brown blue brown ON/OFF blue blu e LOVATO LOVATO blue BF09 BF09 Main P C B black black black brown Contatto brown b rown Legend electric scheme Single phase Neutral Selected Phase from Contactor Electric Pump Control of contact TS on Contactor of power (C-NO) Sanitary Microswitch (control Comfort function) Control gate triac n°1 (4KW power) Control gate triac n°2 (2KW power)
  • Page 14 TRIAC – Connection scheme...
  • Page 15 MANUFACTURE CONSTANTS FUNCTION Value DELTA OFF TANK PROBE 0°C DELTA ON TANK PROBE -1°C INTERVENTION TEMPERATURE ANTI LEGIONELLA 65°C INTERVENTION INTERVAL ANTI LEGIONELLA 7 Days MAX TEMPERATURE PRIMARY 80°C TIME OF PUMP FUNCTIONING IN ANTI-LOCK 10 sec INTERVENTION TIME ANTI-LOCK PUMP TEMPERATURE ANTIFREEZE ON (only circulator) 7°C TEMPERATURE ANTIFREEZE ON (heat exchanger ignition)
  • Page 16 CONTROL OF MAIN HEAT EXCHANGER According to the required power during the heat request, the controls G1-G4 related to the main exchanger are turned on all or partially. The actuation of each control is reduced to a lapse of 4 seconds. Higher is the required power, more the control will remain operative in this lapse.
  • Page 17 Installation and functioning at sliding temperature For the connection of the external probe, it shall be used the Original Kit FIAMMA code F.532 provided in the accessories of the electric boilers Elektra. The electrical connection shall be done in the external terminal at the general electric panel already prearranged in the standard cabling of the boiler.
  • Page 18 ANTIFREEZE FUNCTION In case the delivery probe measures a temperature lower than 7°C, the circulator is activated. If the temperature goes down the value of 4°C the m ain heat exchanger is ignited until the delivery temperature has reached 20°C. The antifree ze function is active also with the boiler turned OFF (function in standby mode but with bright switch on).
  • Page 19 INSTRUCTION GRUNDFOS PUMP HEATING REQUEST As the contact of room thermostat closes, if the mainboard is in winter mode, the system pump is only activated if the temperature of the primary heat exchanger is higher than the temperature set by parameter N°6.
  • Page 20 “Heating elements status” The dashes located in the upper part indicate the heating elements status. Each dash corresponds to a 2 kW element. The first 6 dashes refer to heating modules of primary heat exchanger. The dash on the right upper corner refers to the heating module dedicated to the tank (only if JP8=0 and JP9=0)..
  • Page 21 “Temperature display” On the small digit will appear the writing t : followed by the description of the selected temperature, while the big digit will show the temperature value. FUNCTION N° DELIVERY TEMPERATURE t: “Ch” TANK TEMPERATURE t: “Dh” EXTERNAL TEMPERATURE t: “Ep”...
  • Page 22 FUNCTIONING WITH REMOTE CONTROL ENCRONO OT1, OT2 or OT11 LOOK OF THE REMOTE CONTROL ENCRONO OT1, OT2 and KRONOS OT11 Elektra … BP-L, can be connected by means of its card and an additional module to install on a prearranged part, to a compatible remote control device Opentherm®, like Encrono OT1 or OT2 or OT11.
  • Page 23 Parameters Table FUNCTION N° def. RANGE EXTERNAL PROBE ENABLING 0 – 1 BUILDING LEAKAGE COEFFICIENT 5 – 35 °C SANITARY POST CIRCULATION 1 – 180 sec HEATING POST CIRCULATION 1 – 180 sec HEATING EXCHANGER CIRCUL. START 0 – 240 sec MIN.
  • Page 24 CONTROL PANEL IN INSTALLER MODE The keys have the same functioning described on par. “Control panel in user mode”. DISPLAY OF MALFUNCTIONS CODE “Err” MEANING F 009 Hardware eeprom fault F 001 Insufficient water pressure in the system F 004 Tank probe error / instant sanitary - only if JP8 = 0 F 003 Boiler delivery probe error...
  • Page 25 SPARE PARTS Particular Particular : Boiler body / resistances...
  • Page 26 Upper particular / resistance Front unit Particular : Flange/probe/resistance/anode group Sanitary tank. The flange/tank group, included in one vitrified piece, sheath probe, resistan ce probe, and inspection and support flange. The substitution of the anode magnesium involves the disassembly of the group.
  • Page 27 Spare parts - Legend Upper closing fairing of Elektra .. B/BP-L. ………………...………. Cod.P.2025 Tetrapolar Terminal block . …………..………...Cod.P.2054 for Elektra 6/12/18 … Tetrapolar Terminal block . ………………..………... for Elektra 24 … Terminal of the electric supply line 230V (Ph). …………..….... Cod.P.2073 Terminal of the electric supply line 230V (blue - N).
  • Page 28 Green Acres – Oakley Green Road – WINDSOR BERKSHIRE SL4 4QF. Tel. 01628.636099 – 01628.676900 – Fax. 01628.676958 - E-mail : euroboilerparts@hotmail.co.uk www.euroboilerparts.co.uk FIAMMA GIRO s.r.l. Company group Sede legale e stabilimento : via L. Landucci n° .2/B - 51100 PISTOIA - ITALY Tel.(+39).0573.532812 Fax.(+39).0573.532890 - E.mail : fiammaPT@fiammagiro.it...

Table of Contents