• Adjustment Method of CHGV_L
(item number: 751)
Note: Remove the rechargeable battery.
Remote commander LCD display
751
ChgV L **
** : Adjusted value
1. Connect a digital voltmeter to the TP953(BATT +) and
TP954(BATT −) on the MAIN board, and adjust
[VOL --]
(voltage up) or
key (voltage down) so that the voltage
becomes 1.35 ± 0.01V.
MAIN board
TP953 (BATT+)
TP954 (BATT-)
2. Press the u key on the set or the
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
• Adjustment Method of CHGV_H
(item number: 752)
Note: Remove the rechargeable battery.
Remote commander LCD display
752
ChgV H **
** : Adjusted value
1. Connect a digital voltmeter to the TP953(BATT +) and
TP954(BATT −) on the
[VOL +]
MAIN board, and adjust
key (voltage down) so that the voltage becomes 1.80 ± 0.01V.
MAIN board
TP953 (BATT+)
TP954 (BATT-)
2. Press the u key on the set or the
commander to write the adjusted value.
Adjustment and Connection Location: MAIN board
• Adjustment Method of CIL (Charge current)
(item number: 753)
Note: Remove the rechargeable battery.
1. Make a solder bridge to short TAP951 on the MAIN board (in
order to connect R964(47Ω) between TP953(BATT +) and
TP954(BATT −))
2. Turn on the power.
16
[VOL +]
key
digital
voltmeter
key on the remote
(see page 17)
[VOL --]
key (voltage up) or
digital
voltmeter
key on the remote
(see page 17)
3. Set the manual mode of the test mode and set the item number
753 (see page 10).
Remote commander LCD display
753
CIL **
** : Adjusted value
4. Connect a digital voltmeter to the TP953(BATT +) and
TP954(BATT −) on the MAIN board, and adjust the
[VOL --]
key (voltage up) or
voltage becomes 1.41 ± 0.02V.
MAIN board
TP953 (BATT+)
TAP951
R964 (47 Ω )
TP954 (BATT-)
5. Press the u key on the set or the
commander to write the adjusted value.
6. Turn off the power and open the solder bridge on TAP951 on
the MAIN board.
Adjustment and Connection Location: MAIN board
• Adjustment Method of CIH (Charge current)
(item number: 754)
Note: Remove the rechargeable battery.
1. Make a solder bridge to short TAP952 on the MAIN board (in
order to connect R965(10Ω) between TP953(BATT +) and
TP954(BATT −))
2. Turn on the power.
3. Set the manual mode of the test mode and set the item number
754 (see page 17).
Remote commander LCD display
754
CIH **
** : Adjusted value
4. Connect a digital voltmeter to the TP953(BATT +) and
TP954(BATT −) on the MAIN board, and adjust the
[VOL --]
key (voltage up) or
voltage becomes 1.40 ± 0.02V.
MAIN board
TP953 (BATT+)
TAP952
R965 (10 Ω )
TP954 (BATT-)
5. Press the u key on the set or the
commander to write the adjusted value.
6. Turn off the power and open the solder bridge on TAP952 on
the MAIN board.
Adjustment and Connection Location: MAIN board