• Description of error indication codes
Problem
No error
Servo system error
TOC error
Power supply system error
Offset system error
• Description of indication history
History code number
1
The first error
N
The last error
N1
One error before the last.
N2
Two errors before the last.
Reset the Error Display Code
After servicing, reset the error display code.
• Setting method of reset the error display code
1. Set the test mode (see page 9).
[GROUP]
2. Pressing the
key or pressing the
the remote commander activates the self-diagnosis result dis-
play mode.
3. To reset the error display code, press the u key or
on the remote commander (twice) when the code is displayed.
Remote commander LCD display
(Key pressing at the first time)
000
C l r O K ?
Remote commander LCD display
(Key pressing at the second time)
000
E r r C L R
(All the data on the 1, N, N1, and N2 will be reset)
12
Indication code
Meaning of code
00
No error
Illegal access target
01
address was specified
02
High temperature
03
Focus error
04
Spindle error
11
TOC error
12
Data reading error
13
TOC address error
22
Low battery
31
Offset error
Focus error ABCD
32
offset error
Tracking error
33
Offset error
X1 tracking error
34
Offset error
MD DATA 2
35
Disc error
36
Mirror error
Description
[DISPLAY]
key on
Simple display
----
Adrs
Temp
Fcus
Spdl
TOC
Data
Tadr
LBat
Ofst
ABCD
TE
X1TE
MD2
Mirr
key
Description
No error
Attempt to access an abnormal address
High temperature detected
Disordered focus or can not read an address
Abnormal rotation of disc
Faulty TOC contents
Data could not be read at SYNC
TOC address data error
Momentary interruption detected
Offset error
Focus error ABCD offset error
Tracking error Offset error
X1 tracking error Offset error
MD DATA 2 disc error
Mirror decision retry over