Free Standing/Portable Use

The heater may be used free standing in either the
upright or lay-flat position as shown The heater
incorporates a permanently fixed wall mounting bracket
for use when the heater is installed as a fixed appliance,
and which acts as a stand when in either position.
Reference should be made to the section "Heater
Dimensions and Minimum Operating Distances" before
use
WARNING - IF THE HEATER IS FREE
STANDING IT MUST NOT BE USED IN THE
IMMEDIATE SURROUNDINGS OF A BATH. A
SHOWER OR A SWIMMING POOL

FIXING THE HEATER

The heater may be fixed to the wall or floor using
the fixing holes provided in the mounting frame. Please
refer to the Section "Heater Dimensions and Minimum
Operating Distances" before fixing the heater in position

Fixing to the Wall

WARNING - The heater must NOT be located
immediately below a fixed socket outlet
The heater must be fixed only in the upright position
with the control panel at the bottom. The position of the
two upper fixing points should first be marked on the
wall, at a horizontal distance of 100mm apart, Diagram
A. Place the heater in position with the upper wall
bracket notches against these fixing points to check that
the heater complies with the "minimum operating
distances". These two fixing points should then be
drilled and plugged. Suitable round headed size 8
screws should be fixed in these positions to such a
depth that the heater may be hung in position while the
positions of the lower fixing holes are marked, Diagram
B. The heater should then be removed while the lower
fixing holes are drilled and plugged. Then the heater
should be hung in position on the upper two screws
while the lower two screws are tightened to hold the
heater firmly on the wall. The tightness of the upper
screws should be adjusted if necessary to ensure a firm
fit.

Fixing to the Floor

The heater may be fixed to the floor in the lay-flat
position. Before fixing the heater in position place it in
the desired position and check that it complies with the
requirements described in the section "Heater
Dimensions and Minimum Operating Distances".
For guidance on fixing the heater see the section on
'Fixing to the Wall". The principles involved are the
same.