Sony TC-SP55 Service Manual page 12

Stereo cassette deck
Hide thumbs Also See for TC-SP55:
Table of Contents

Advertisement

QQ
3 7 63 1515 0
3. Phase check
Model: FWD playback
test tape
P-4-A100
(10kHz, –10dB)
L-CH
set
R-CH
4. Perform steps 1 to 3 in the FWD playback mode.
5. Confirm that phase error between L-ch and R-ch is in the range
of same phase to 90 degrees.
6. After the adjustments, apply suitable locking compound to the
parts adjusted.
Waveform of oscilloscope
in phase
45°
90°
good
Adjustment Location:
Adjustment scerw
(REV mode)
TE
L 13942296513
Tape Speed Adjustment
Procedure:
test tape
WS-48B
(3kHz, 0dB)
set
1. Insert the WS-48B into deck.
www
2. Press the H button of deck.
3. Adjust RV362 of the MAIN board so that the reading of the
frequency counter becomes 3000 ± 90 Hz.
.
Adjustment Location: MAIN board
Sample Value of Wow and flutter
W.RMS (JIS) less than 0.3%
(test tape: WS-48B)
12
http://www.xiaoyu163.com
oscilloscope
47kW
V
H
47kW
AUX OUT
(on ST-SP55)
135°
180°
wrong
Adjustment scerw
(FWD mode)
level meter
AUX OUT
(on ST-SP55)
x
ao
u163
y
i
http://www.xiaoyu163.com
2 9
8
Playback Level Adjustment
Procedure:
Mode: FWD playback
test tape
P-4-L300
(315Hz, 0dB)
set
Adjust RV211 (L-CH) and RV261 (R-CH), so that adjustment within
the following adjustment level.
Adjustment level:
AUX OUT level: –8.2 ± 0.5 dB (285 to 319 mV)
Level difference between the channels: within ± 1.0 dB
Confirm that the AUX OUT level does not change even though
play and stop are repeated.
Record Bias Adjustment
Procedure:
1. Record mode.
AUX IN (on ST-SP55)
1) 315 Hz
2) 10 kHz
Q Q
AF OSC
3
6 7
1 3
1 5
600 Ω
attenuator
2. Playback mode.
recorded
position
set
3. Confirm playback the signal recorded in step 1 become adjust-
ment level as follows.
Note: You had better to refer "4-1-4. TC REC START POINT"
See page 9) when this adjustment
4. If these levels do not adjustment level, adjust the RV311 (L-CH)
and RV361 (R-CH), to repeat steps 1 to 3.
Adjustment level:
The playback outpout of 10 kHz level difference adjust
315 Hz reference should be 0 dB ± 0.5 dB.
co
.
9 4
2 8
level meter
AUX OUT
(on ST-SP55)
} 50 mV (–23.8 dB)
0 5
8
2 9
9 4
2 8
blank tape
CS-123
set
level meter
AUX OUT
(on ST-SP55)
m
9 9
9 9