3-22 Diagnostic Tools
POST Error Messages
1790-Disk 0
Configuration
Error
1791-Disk 1
Error
1792-Drive
Array Reports
Valid Data
Found in Array
Accelerator.
Data will
automatically be
written to drive
array.
1793-Drive
Array - Array
Accelerator
Battery
Depleted - Data
Lost
(Error message
1794 also
displays.)
Continued
Audible
Error Code
Beeps
L=Long
S=Short
None
None
None
None
Probable Source of
Problem
Hard drive error or
wrong drive type
Hard drive error or
wrong drive type.
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory. Power was
then restored within
eight to ten days, and
the data in the Array
Accelerator was flushed
to the drive array.
This indicates that while
the system was in use,
power was interrupted
while data was in the
Array Accelerator
memory.
Array Accelerator
batteries failed. Data in
Array Accelerator has
been lost.
Action
Run the System
Configuration Utility and
Diagnostics and correct.
Run the System
Configuration Utility and
Diagnostics and correct.
No action necessary; no
data has been lost.
Perform orderly system
shutdowns to avoid data
remaining in the Array
Accelerator.
Power was not restored
within eight to ten days.
Perform orderly system
shutdowns to avoid data
remaining in the Array
Accelerator.

Advertisement

Table of Contents
loading

Table of Contents