INSTALLATION
Continued
LOCATING HEATER
WARNING: Maintain the
minimum clearances shown
in Figure 4. If you can, provide
greater clearances from floor,
ceiling and joining wall.
You can locate heater on the floor, away from
a wall. A wall mounting bracket and floor base
stand are included with this heater. Determine
which method is best for your application.
WARNING: Never install the
heater
• in a bedroom or bathroom
• in a recreational vehicle
• where curtains, furniture, cloth-
ing or other flammable objects
are less than 36" from the front,
top or sides of the heater
• as a fireplace insert
• in high traffic areas
• in windy or drafty areas
CAUTION: If you install the
heater in a home garage
• heater pilot and burner must
be at least 18" above floor
• locate heater where moving
vehicle will not hit it
CEILING
10"
Minimum
From
Sides Of
Heater
Left
Side
FLOOR
Figure 4 - Mounting Clearances As
Viewed From Front of Heater
8
ates warm air currents. These
currents move heat to wall sur-
faces next to heater. Installing
heater next to vinyl or cloth wall
coverings or operating heater
where impurities (such as, but
not limited to, tobacco smoke,
aromatic candles, cleaning flu-
ids, oil or kerosene lamps, etc.) in
the air exist, may discolor walls
or cause odors.
IMPORTANT: Vent-free heaters add moisture
to the air. Although this is beneficial, installing
heater in rooms without enough ventilation
air may cause mildew to form from too much
moisture. See Air for Combustion and Ventila-
tion, page 5. If high humidity is experienced,
a dehumidifier may be used to help lower the
water vapor content in the air.
For convenience and efficiency, install heater
• where there is easy access for operation,
• in coldest part of room
An optional fan kit is available from your
dealer. See Accessories, page 26. If planning
to use fan, locate heater near an electrical
outlet.
THERMOSTAT SENSING BULB
(Thermostat Models Only)
The thermostat sensing bulb has been placed
below the heater.
1. Place clamp on thermostat sensing bulb
2. Snap clamp into upper mounting hole
36"
Minimum
Right
Side
2"
Minimum To
Top Surface
Of Carpeting,
Tile Or Other
Combustible
Material
Figure 5 - Attaching Thermostat Sensing
www.desatech.com
CAUTION: This heater cre-
inspection and service
as shown in Figure 5. Clamp is provided
in hardware package.
as shown in Figure 5. Mounting hole is
located on lower left edge on back of
heater. Make sure the thermostat sensing
bulb is pointing up.
Bulb
Thermostat
Sensing
Bulb
Clamp
119342-01B