Kenwood TK-3302 Service Manual Supplement page 5

Hide thumbs Also See for TK-3302:
Table of Contents

Advertisement

4-3. Operation
1. To switch the clone target/s to wireless clone mode,
press and hold the [PTT] and [side2] keys while turning
the transceiver power ON.
2. Wait for 2 seconds. The LED will light orange and the
transceiver will announce "Clone".
3. Select a channel table number using Side1 (increment
channel table) and Side2 (decrement channnel table)
keys.
4. To switch the clone source to wireless clone mode, press
and hold the [PTT] and [side2] keys while turning the
transceiver power ON.
5. Wait for 2 seconds. The LED will light orange and the
transceiver will announce "Clone".
6. Select the same channel table number as the clone
target/s.
7. Press [PTT] on the clone source to begin data transmis-
sion.
When the clone target starts to receive data, the LED will
light green.
When the clone source fi nishes sending data, a "confi r-
mation" tone will sound.
If data transmission fails while cloning, an "error" tone
will sound from the target unit.
8. If the cloning fails, no data will be available in the target
unit when it is returned to User mode.
9. When the cloning is successful, the target unit's "Scan"
and "Key lock" functions will return to their default values
(Scan = OFF, Key lock = OFF).
Notes:
• The dealer can clone data to two or more transceivers by
repeating the above procedures.
• If the transceivers wireless clone mode is confi gured as
"Disabled", the transceiver cannot enter wireless clone
mode.
• The table shown below will cover the frequency tables
used for wireless cloning.
• Wireless clone mode cannot be entered in battery low
state.
• A unit cannot be a "Source Unit" if it is unprogrammed. If
[PTT] is pressed, an "error" tone will sound.
• The language used in cloning depends on the "Model
type" setting, not the FPU setting.
• Once a unit is set to be the source, it cannot be a target
after the data has been transmitted. This protects the
data in the source unit.
• Electronic interface may cause a failure in data transfer
during wireless clone, such as when waveforms or elec-
tromagnetics are being performed at the workbench.
• Wireless clone mode can be used ONLY by the autho-
rized service personnel.
• The wireless clone mode setting must be confi gured
as "Disable" before being delivered to the end-user.
• To clone, replace the antenna from both the source
transceiver and the target transceiver with a dummy
load.
• The transmit output power is automatically set to
Low in wireless clone mode.
REALIGNMENT
• Clone frequency table
No.
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
19
20
TK-3302
Operating frequency (MHz)
TK-3302 K2,M2
TK-3302 K3
470~512
400~430
472.000
400.000
474.000
401.000
476.000
402.000
478.000
403.000
480.000
404.000
482.000
405.000
484.000
406.000
486.000
407.000
488.000
408.000
490.000
409.000
492.000
410.000
494.000
411.000
496.000
412.000
498.000
413.000
500.000
414.000
502.000
415.000
504.000
416.000
506.000
417.000
508.000
418.000
510.000
419.000
5

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents