Removing Of Major Parts - Sharp XG-NV2SB Service Manual

Hide thumbs Also See for XG-NV2SB:
Table of Contents

Advertisement

1. Removing the Intake cover, lamp unit and lens cover
1-1. Detach the Intake cover.
1-2. Remove the screw off the lamp cage cover and detach the lamp cage cover.
1-3. Remove the three lock screws off the lamp cage unit and detach the lamp cage unit.
1-4. Remove the lock screw from the lens cover. Turn the lens cover clockwise or counterclockwise and detach it.
Notes:
» Before the replacement, turn off the projector's power button, make sure the cooling fan comes to a complete
stop, and unplug the power cord.
» The lamp may be still very hot. Turn off the power button, unplug the power cord and wait for at least 1 hour
before staring the job.
» In fitting the lamp cage unit back into position, make sure the connector is at the top position.
Lens Cover

REMOVING OF MAJOR PARTS

1-4
Intake Cover
1-1
1-2
13
XG-NV2SB
Lamp Cage Unit
1-3
Lamp Cage Cover