<Additional work to the side-B.>
<Procedure>
(1) Cover IC8302 and IC8304 on the PWB's Side B with the electromagnetic wave absorber (PSLDMA530WJZZ-
- -60x45 mm). Be careful not to confuse the absorber's setup direction.
~Positioning guide for the electromagnetic wave absorber
• Adjust the absorber to the edges of IC8302 and IC8304. See the figure at left for positioning C.
• Adjust the absorber to the lower edge of the PWB screw hole. See the figure at left for positioning D.
(2) To prevent the absorber from peeling off, apply silicone adhesive at two points between the absorber and the
PWB. See the figure at left for adhesive applications C and D.
Silicone adhesive for servicing.
Part No,
ZSLCN-098P2KE
Maker:Shin-Etsu Chemical Co., Ltd.
Number:KE3490
Description
J
200g (1 tube)
Adhesive application C
Positioning D
45 mm side
Code
BH
6
Positioning C
Adhesive application D