Sharp PG-F310X Service Manual page 27

Hide thumbs Also See for PG-F310X:
Table of Contents

Advertisement

No.
Adjusting point
14
DVI input operation check
15
Monitor out check
16
RS232C operation check
17
USB operation check
18
Model name and version check
19
LAN operation check (XG-F315X
only)
20
Delivery settings
* Writing a software program (before main PWB is mounted)
Use the DLP Composer Lite Ver. 7.0 or higher to download the firmware.
* "Skip Boot Loader Area" set to "32KB"
After writing the specified version of firmware to the PWB using the RS232C cable, check the version of the written firmware.
If no software program is written, all three LEDs light up in the chassis inspection process.
Calling and quitting the process mode with the control keys on this model.
* Although it is possible for the process OUT to exit using the process menu, the IN/OUT toggle command is also available considering the existing
specification.
1) Calling and quitting
With the menu not displayed, press the "ENTER", "ENTER", "VOL+", "VOL-", "ENTER", "ENTER" and "MENU" keys on the remote control or on
the main unit.
2) Others
Press the S2551 process key (toggle) on the main PWB to call and quit the process menu.
NOTE: When adjusting in the process mode, set a signal with a vertical frequency of 60 Hz or no signal. (May not be properly adjusted with other sig-
nals.)
Resetting the lamp timer for this model
1) Resetting procedure
In Stand-by, run this command to clear the operating time of the lamp to 0 and turn on the power.
Press and hold " ", "ENTER", and "MENU", and then press the "STANDBY/ON" key of the set.
Forced disabling of the System-Lock of this model
1) Disabling procedure
With System-Lock input window onscreen, press the "MENU", "ENTER", "ENTER", "MENU", "ENTER", "ENTER" and "MENU" keys, in this order,
on the remote controller.
Adjusting conditions
1) Send the video signal to the DVI terminal. 1) Check that an image is properly projected through
1) Send signals to COMPUTER 1 and
COMPUTER 2.
2) Connect another monitor to the monitor
out.
3) Connect the audio OUT.
1) Connect the unit and a PC with the
RS232C cable.
1) Connect to a PC with an USB cable.
1) Select the following group.
Group: INFO/VERSION.
1) Connect to a PC with a LAN cable.
1) Make the following settings.
Destination
Process
adjustment
USA
SS4
China
SS6
Others
SS3
4 – 3
PG-F310X/XG-F315X
Adjusting procedure
the digital input and analog input.
1) Check that the same images as seen on the
screen appear on the connected monitor and that
the sound from the sound source connected to the
audio OUT is heard.
1) Send a command from the PC, and check it func-
tions correctly.
1) Check that page up/down is enabled using the
remote control.
1) The model name appears in the MODEL field, and
the firmware version in the VERSION field.
Check that they are correct.
1) Check that communication is possible.
Remote control
adjustment
Factory setting at 4
Factory setting at 6
Factory setting at 3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Xg-f315x

Table of Contents