Electrical Adjustments - Sony MZ-N520 Service Manual

Hide thumbs Also See for MZ-N520:
Table of Contents

Advertisement

Outline
• In this set, automatic adjustment of CD and MO can be per-
formed by entering the test mode.
However, before starting automatic adjustment, the memory
clear, power supply adjustment, and laser power check must be
performed in the manual mode.
• A key having no particular description in the text, indicates a
set key.
Precautions for Adjustment
1. Adjustment must be done in the test mode only.
After adjusting, release the test mode.
2. Use the following tools and measuring instruments.
• Test CD disc
TDYS-1
(Part No. : 4-963-646-01)
• SONY MO disc available on the market
• Digital voltmeter
• Laser power meter
LPM-8001
(Part No. : J-2501-046-A)
• Thermometer (using the Temperature Correction)
• Personal computer
• USB cable
3. Unless specified otherwise, supply DC 3V from the DC IN 3V
jack (J951).
4. Switch position
HOLD switch ............................................... ON
Adjustment Sequence
1. NV Reset (item number: 021)
(EEPROM clear)
r
2. Temperature Correction (item number: 015)
r
3. Power Supply Manual Adjustment
r
4. Laser Power Check
r
5. Adjustment required before Overall
Adjustment
r
6. CD Overall Adjustment (item number: 031)
r
7. MO Overall Adjustment (item number: 034)
r
8. RESUME Clear (item number 043)
r
9. Rewriting the Patch Data
(at replacement of the MAIN board)
r
10. Rewriting the NV values
Note: In the case of the microcomputer version 1.200 or more, the
sequence 5. Adjustment required before Overall Adjustment is
unnecessary.
NV Reset
• Setting Method of NV Reset
1. Select the manual mode of the test mode, and set item number
021 NV Reset (see page 14).
Set LCD display
0 21
SECTION 5

ELECTRICAL ADJUSTMENTS

Manual Mode
Overall Mode
Manual Mode
* * * S C C
2. Press the
key.
X
Set LCD display
0 21
3. Press the
key once more.
X
Set LCD display
0 21
0 21
4. Press the xCANCEL/CHG key to quit the manual mode, and
return to the test mode (display check mode).
Temparature Correction
• Adjustment Method of Temperature Correction
1. Select the manual mode of the test mode, and set the item num-
ber 015 (see page 14).
Set LCD display
0 15
2. Measure the ambient temperature.
[VOL +]
[VOL --]
3. Adjust with
or
(hexadecimal value) becomes the ambient temperature.
(Initial value : 19h = 25˚C, Adjusting range : 80h to 7fh
(–128˚C to +127˚C))
4. Press the
X
key or press the
to write the adjusted value.
Power Supply Manual Adjustment
• Adjustment sequence
Adjustment must be done with the following steps.
1. VC1_LOW (PB) adjustment (item number : 741)
2. VC1_HIGH (REC) adjustment (item number : 742)
3. VC2_LOW adjustment (item number : 743)
4. VC2_HIGH adjustment (item number : 744)
5. REG1 adjustment (item number : 745)
6. REG3_LOW1 adjustment (item number : 747)
7. REG3_LOW2 adjustment (item number : 748)
8. REG3_HIGH adjustment (item number : 749)
9. VREC_LOW (X2 speed) adjustment (item number : 751)
10. VREC_MIDDLE (X4 speed)adjustment (item number : 752)
11. VREC_HIGH (HEAD MOTOR) adjustment (item number : 753)
12. CHGV_LOW adjustment (item number : 755)
13. CHGV_HIGH adjustment (item number : 756)
14. CHGI_LOW (current) adjustment (item number : 757)
15. CHGI_HIGH (current) adjustment (item number : 758)
• Setting Method of Power Supply Manual Adjustment
1. Make sure that the power supply voltage is 3V.
2. Select the manual mode of the test mode (see page 14).
3. Set item number.
Note1: BATT- terminal is not GND when AC adaptor is used.
Note2: Power supply adjustment auto item feed mode (page 25) is
available to perform the temperature Correction and Power
Supply Adjustment without entering the manual mode.
MZ-N520/N520CK
R e s O K ?
R e s * * *
NV reset (after several seconds)
R e s e t !
S e t T m p
key so that the adjusted value
key on the remote commander
--
19