5-3-4. LCD display check
LCD display is checked.
Checking method:
1. Enter the test mode.
2. Press the [>] key to display major item, and press the [E] [e]
key to select the "OTHERS".
LCD display
OTHERS
3. Press the [>] key to display minor item, and press the [E] [e]
key to select the "LCD 1".
LCD display
LCD 1
4. Press the
key, LCD all segments of main unit and remote
u
commander are turned on.
key to display minor item, and press the [E] [e]
5. Press the
x
key to select the "LCD 2".
LCD display
LCD 2
6. Press the
key, LCD all segments of main unit and remote
u
commander are turned off.
key to display minor item, and press the [E] [e]
7. Press the
x
key to select the "LCD 3".
LCD display
LCD 3
8. Press the
key, monochrome lattice is displayed on the LCD
u
of main unit.
key to display minor item, and press the [E] [e]
9. Press the
x
key to select the "LCD 4".
LCD display
LCD 4
10. Press the
key, monochrome lattice (reverse version of step
u
8) is displayed on the LCD of main unit.
11. Press the
key, return to minor item selection screen.
x
5-3-5. G-sensor adjustment
X/Y/Z-axis direction is adjusted.
Adjustment method:
1. Enter the test mode.
2. Press the [>] key to display major item, and press the [E] [e]
key to select the "OTHERS".
LCD display
OTHERS
3. Press the [>] key to display minor item, and press the [E] [e]
key to select the "G CLB".
LCD display
G CLB
4. Press the
key, "+X" is displayed. Main unit is fixed so that
u
1 of fig.1 may become downward and press the
LCD display
+X
16
5. "–X" is displayed. Main unit is fixed so that 2 of fig.1 may
become downward and press the
LCD display
6. "+Y" is displayed. Main unit is fixed so that 3 of fig.1 may
become downward and press the
LCD display
7. "–Y" is displayed. Main unit is fixed so that 4 of fig.1 may
become downward and press the
LCD display
8. "+Z" is displayed. Main unit is fixed so that 5 of fig.1 may
become downward and press the
LCD display
9. "–Z" is displayed. Main unit is fixed so that 6 of fig.1 may
become downward and press the
LCD display
10. "CALIB" is displayed. Press the
Then "FIN", "DAT NG" or "SEN NG" is displayed automatically.
LCD display
FIN
DAT NG : The data for performing a calibration is faulty.
SEN NG : The value acquired from the G-sensor is faulty.
11. Press the
Fig.1 Axis direction of G-sensor adjustment
key.
u
key.
u
-X
key.
u
+Y
key.
u
-Y
key.
u
+Z
key.
u
-Z
key, G-sensor is adjusted.
u
CALIB
r
FIN
: adjusted normally.
key, return to minor item selection screen.
x
4
6
2
3
1
5

Hide quick links: