Electrical Device Use With The Zr-8 - Red-D-Arc ZR-8 Operator's Manual

Hide thumbs Also See for ZR-8:
Table of Contents

Advertisement

TABLE II Maximum Current Draw from 115V GFCI Duplex Receptacles - No Welding
Load From
115V/230V
Dual Voltage
Receptacle
0
1.1 KW
3.4 KW
5.7 KW
8.0 KW
*Maximum current draw from each 115V GFCI Duplex is 20 amps
Type
Resistive
Capacitive
Inductive
Capacitive/Inductive
The Lincoln Electric Company is not responsible for any damage to electrical components improperly connect-
ed to the ZR-8
Each 115V
Duplex
20
20
20
20
0

ELECTRICAL DEVICE USE WITH THE ZR-8

Common Electrical Devices
Heaters, toasters, incandescent
light bulbs, electric range, hot
pan, skillet, coffee maker.
TV sets, radios, microwaves,
appliances with electrical control.
Single-phase induction motors,
drills, well pumps, grinders, small
refrigerators, weed and hedge
trimmers
Computers, high resolution TV sets,
complicated electrical equipment.
Total From
Both 115V
Duplexes
40*
40*
40*
20*
0
TABLE lll
– 21 –
Possible Concerns
NONE
Voltage spikes or high voltage
regulation can cause the capac-
itative elements to fail. Surge
protection, transient protection,
and additional loading is recom-
mended for 100% fail-safe
operation. DO NOT RUN
THESE DEVICES WITHOUT
ADDITIONAL RESISTIVE TYPE
LOADS.
These devices require large
current inrush for starting.
Some synchronous motors may
be frequency sensitive to attain
maximum output torque, but
they SHOULD BE SAFE from
any frequency induced failures.
An inductive type line condition-
er along with transient and
surge protection is required,
and liabilities still exist. DO
NOT USE THESE DEVICES
WITH A ZR-8.