Circuit Protection - Chariot CB20 Operating Instructions Manual

Table of Contents

Advertisement

1.
CIRCUIT BREAKERS
Circuit breakers interrupt the flow of power in the
event of an electrical overload. When a circuit
breaker is tripped, reset it by pressing the
exposed button. If a circuit breaker continues to
trip, the cause of the electrical overload should
be found and corrected.
Downloaded from
www.Manualslib.com
1
30 Amp. Protects the propel
motor.
3 Amp. Protects the machine
controls. (Basic only).
86306300 CHARIOT BURNISHER 11/09/07
manuals search engine
MAINTENANCE-CIRCUIT PROTECTION
2
2.
FUSE
The fuse is a one-time circuit protection device
designed to stop the flow of electrical current in
the event of an electrical overload. The fuse
protects the burnisher pad motor and controller.
If fuse is blown, it must be replaced.
The fuse is located inside the battery
compartment.