NuTone SmartSense QT110H Installation Instructions page 2

Automatic fan combintion

Advertisement

CONNECTOR
MOTOR PLUG
JUNCTION BOX
WIRING CONNECTIONS
WIRING
Refer Figure 2.
1. Run 120v AC house power wiring (with ground) through switch box to
junction box in ventilator housing.
2. Remove ventilator junction box cover.
3. Referencing figure 2 connect the house power wire (black) to the
connector black wire. Connect the house neutral wire (white) to both
the connector and motor plug wires (white). Connect the ground wire
to the green ground screw. Connect the blue connector wire to the
black motor plug wire.
4. Replace junction box cover.
5. Connect house power wire to standard toggle switch.
NOTE: BE SURE VENTILATOR AND SWITCH ARE PROPERLY
GROUNDED. ALL WIRING MUST COMPLY WITH LOCAL
ELECTRICAL CODES.
SENSOR UNIT INSTALLATION
Refer Figure 3.
1. Align sensor cover tabs with slots in junction box cover. Firmly
press sensor cover to engage connector.
2. Secure sensor unit using mounting screw through hole in unit
cover flange.
POWER/BLOWER UNIT INSTALLATION
1. Plug motor into socket in housing's junction box.
2. Position power unit mounting plate over mounting screws in
housing.
3. Slide unit forward until the gasket fits firmly against discharge
opening in housing and mounting screws are seated in narrow
end of keyhole slots.
4. Refer to Figure 4. Securely tighten screws.
GRILLE INSTALLATION
1. Refer to Figure 4. Snap grille mounting springs' center loop into
notched bosses on the back of grille.
2. Place grille mounting springs into slots in power unit mounting
plate.
3. Press grille firmly into place against the ceiling.
BLACK
BLACK
120 VOLT
AC SUPPLY
WHITE
WHITE
FIGURE 2
JUNCTION
BOX COVER
SENSOR COVER TABS
TIMER ADJUSTMENT
INSTALLATION IN EXISTING CONSTRUCTION
Installing the ventilator in an existing house requires an accessible
area (attic crawl space) above the planned installation location.
Review "INSTALLATION IN A NEW CONSTRUCTION" and
follow all instructions which apply to your installation.
Location – locate ventilator parallel to a ceiling joist.
Wiring and Ducting – plan ducting and wiring before proceeding
with installation.
Refer to Figure 2 for wiring and Figure 1 for ducting.
CAUTION: Check area above planned installation to be sure that:
1. Ducting can be installed.
2. Wiring can be run to the planned location.
3. No wiring or other obstructions might interfere with
installation.
INSTALLATION FROM ACCESSIBLE
AREA ABOVE
1. From below, drill a small hole in ceiling at the planned location.
Stick clothes hanger through hole to help locate it.
2. Locate hole in attic or crawl space.
3. In attic or crawl space, mark ceiling for cutout by using the
housing as a template. The long side of cutout must be parallel
to ceiling joist.
4. Make cutout along marked line.
NOTE: If ceiling is plaster, cutout should be made from below
to avoid chipping plaster.
5. Install housing, connect wiring and ducting, install sensor unit,
install power unit/blower assembly and install grille.
SENSOR
UNIT
FIGURE 3

Advertisement

loading