The Miele DSM 400 control module can
be used to combine the rangehood with
other components.
It enables the following:

Potential free connection

This is used for controlling another
appliance with the help of the
rangehood's On/Off button s.
The potential free contact of the
DSM 400 a can be installed in an
...EXT model, for instance, which is
connected to a central extraction
system.
The contact can be used to activate a
motorised shut-off flap b which is
installed before the central extraction
system c.

Operation with Control module DSM 400

The components of the central
extraction system are not supplied as
standard by Miele.
If in any doubt, the advice of a
competent builder must be sought.

Connection to a light switch

The control module can be used to
switch on the rangehood lighting and
also to dim it, depending on model, via
a light switch in the house.
Installation
The control module is fitted onto the
rangehood housing.
All electrical work must be carried
out by a competent, qualified
electrician.