Technology; Installation - abc 9kW LILLY User Manual

Table of Contents

Advertisement

Storage of Pellets
It is very important that the pellets are stored at the dry place. It is not
advisable to store pellets in bags exposed to atmospheric conditions.
Too wet pellets may block the auger

5.TECHNOLOGY

Your new stove is technologically enhanced as a result of years of
testing and top quality built-in components. The practical advantages
of the Lilly stove are as follows:
§
Electronic monitoring of all devices along with monitoring of
combustion temperature in the firebox guarantees the optimum
operation of stove in all phases.
§
The large heat exchanger surface with the unique control of
combustion air results in low consumption of pellets and high
energy efficiency.
§
Precisely weighed pellet loading to the burner made of special cast
iron leads to perfect combustion resulting in low emission of
hazardous substances into atmosphere.
§
The top quality cast parts such as burner resistant up to 1300 and
doors ensure long and safe operation.

6.INSTALLATION

§
Remove all accessories from the stove (user manual, power cable,
remote controller, etc.).
§
The stove must be connected to the chimney the minimum diameter
of which is 120mm.
§
The combustion air circulation is based on the negative pressure in
the firebox and very low overpressure in the flue pipe. The flue pipes
must fit the diameter of outlet pipes and no leaks shall be detected at
joints.
§
Make sure that the horizontal length of the flue pipe does not exceed
1.5m.
§
Do not install too many elbows (direction changes of flue gases) on
flue pipes. The maximum number of elbows shall be 3.
§
Be sure to leave the room for easy dismantling of the flue pipe and
easy access to the opening for cleaning.
§
The stove must be installed on the fire-proof surface. Should the
surface be flammable (wood, carpet, etc.), it is recommended to set a
fireproof basis (glass, metal, ceramic tiles, etc.)
6