DIP Switches setting

PV037/PV057 DIP Switches setting
SW1
System Menu
ON
Not display system menu, go to ON-LINE communication
after turns on.
Display system menu when turns on. Not go to ON-LINE
OFF
communication.
SW2
Emergency recovery the HMI BIOS to default value.
ON
Set to default OS version or customized OS version.
Set to default BIOS version B.
OFF
SW3
SW4
HMI operation mode (Supports special functions for customized
BIOS version)
OFF
OFF
Reserved
ON
OFF
To execute HMI Communication testing program (SW1,2
must set to Off)
To execute Key adjustment program or Touch adjustment
OFF
ON
program (SW1,2 must set to Off)
To execute HMI application program
ON
ON
SW5
Reserved
ON
Reserved
OFF
Reserved
SW6
Reserved
ON
Reserved
OFF
Reserved
***The PV037/PV057 has a BIOS password recovery system to
prevent confusing when missing password. When you forget the
password, which has been set to the HMI, this HMI can execute RUN
AP/Calibrate operation but can not execute BIOS/Download AP/Clear
SRAM operations. When the users want to download new AP without
password, please set all DIP switches to off (SW1-6=Off), When turns
on HMI again, the HMI will display clean all AP and old password
screen. After proceeding this procedure, the HMI can be operated
normally again.
A-8