Troubleshooting - Agatec DM100 Owner's Manual

Laser
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
10.3 Room volume
Press key 6 twice.
The volume symbol appears on the display.
Press key 4 and measure the first distance
(e.g. length).
Press key 4 and measure the second distance
(e.g. width).
Press key 4 and measure the third distance
(e.g. height).
The device displays the result in the summary row and the respective measured distance to the
next measurement in the second row.

11 Troubleshooting

If the message Error does not disappear after switching on the device repeatedly, please
contact the dealer.
If the message InFo appears with a number, observe the instructions in the following table.
No.
Cause
204 Calculation error
252 Temperature too high
253 Temperature too low
255 Reception signal too
weak, measuring time
too long
256 Input signal too high
257 Measuring error, too
much background light
258 Measurement outside
of the measuring range
260 Laser beam interrupted Repeat the measure-
Correction
Perform measure-
ment again.
Let the device cool
down.
Warm the device up.
Change target sur-
face (e.g. white
paper).
Change target sur-
face (e.g. white
paper).
Shadow the target
area.
Mind the range.
ment.
9/70