Technical Changes - Mitsubishi MSZ-FA25VA Service Manual

Wireless type split-type, heat pump air conditioners
Table of Contents

Advertisement

1

TECHNICAL CHANGES

MSZ-A09YV -
E1
MSZ-A12YV -
E1
1. Indication of capacity has been changed.(BTU base
2. Controller method between indoor and outdoor has been changed.
3. Power supply method has been changed (change to supply from outdoor unit).
4. Power supply cord has been removed.
5. Indoor electronic control P.C. board has been changed.
6. Position of terminal block has been changed.
7. Indoor fan motor has been changed. ( AC
8. Indoor heat exchanger has been changed.
9. The horizontal vane motor unit has been changed.
An external gear is added to the generalized stepping motor.
The unit is structured so that the driving torque and stopping torque would increase.
Generalized stepping motor
NOTE: Do not remove the vane motor from the motor unit.
Do not disassemble the horizontal vane motor unit.
10. The vertical vane motor unit has been added.
An external gear is added to the generalized stepping motor.
The unit is structured so that the driving torque and stopping torque would increase.
NOTE: Do not remove the vane motor from the motor unit.
Do not disassemble the vertical vane motor unit.
11. Front panel driving motor unit which opens and closes the front panel has been added.
NOTE: Do not disassemble the front panel driving motor unit.
12. PLASMA DEODORIZING/AIR PURIFYING filter units have been added.
13. i-see Sensor has been added.
(i-see control operation and AREA setting have been added.)
14. Air cleaning filer has been removed.
15. Signal of remote controller has been changed. (It is not available for the conventional models.)
16. Symbol on terminal block has been changed (to S1/S2/S3).
MSZ-FA25VA -
E1
MSZ-FA35VA -
E1
DC)
Generalized stepping motor
kW base)
Front panel opening/closing
output gear
2

Advertisement

Table of Contents
loading

Table of Contents