MAX. REFRIGERANT PIPING LENGTH
Models
MSH-07NV -
E1
MSH-09NV -
E1
MSH-07NV -
E2
MSH-09NV -
E2
MSH-12NV -
E1
MSH-12NV -
E2
MSH-18NV -
E1
MSH-18NV -
E2
MSH-18NV -
E3
MSH-24NV -
E1
MSH-24NV -
E2
MAX. HEIGHT DIFFERENCE
ADDITIONAL REFRIGERANT CHARGE(R-22 : g)
Models
MSH-07NV -
E1
MSH-09NV -
E1
MSH-07NV -
E2
MSH-09NV -
E2
MSH-12NV -
E1
MSH-12NV -
E2
MSH-18NV -
E1
MSH-18NV -
E2
MSH-18NV -
E3
Models
MSH-24NV -
E1
MSH-24NV -
E2
Refrigerant piping
Max. length : m
A
10
15
Outdoor unit precharged
(up to 7m)
850
1150
1800
Outdoor unit precharged
(up to 7m)
2400
Piping size O.D : mm
Gas
Liquid
9.52
6.35
12.7
15.88
9.52
Refrigerant piping length (one way)
7m
0
Calculation : Xg=50g/m
Refrigerant piping length (one way)
7m
0
Calculation : Xg=65g/m
Length of connecting pipe : m
Outdoor unit
Indoor unit
0.43
10m
15m
150
400
(A-7)m
10m
15m
195
520
(A-7)m
0
27