Multiaqua CFFWA4P 04 Operation And Installation Manual

Multiaqua CFFWA4P 04 Operation And Installation Manual

Universal mount fan coil unit (4-pipe)

Advertisement

UNIVERSAL MOUNT
FAN COIL UNIT (4-Pipe)
________________________________________________________________________________
Operation and Installation Manual
CFFWA4P 04, 08, 12, 16 & 20
4-Pipe Universal Mount Fan Coil Unit
Please read this manual before using the fan coil unit.
Installation and service must be carried out by trained and qualified technicians only.
Rev. 1.3

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CFFWA4P 04 and is the answer not in the manual?

Questions and answers

Summary of Contents for Multiaqua CFFWA4P 04

  • Page 1 FAN COIL UNIT (4-Pipe) ________________________________________________________________________________ Operation and Installation Manual CFFWA4P 04, 08, 12, 16 & 20 4-Pipe Universal Mount Fan Coil Unit Please read this manual before using the fan coil unit. Installation and service must be carried out by trained and qualified technicians only.
  • Page 2 GENERAL Read the entire contents of this manual before beginning installation. Multiaqua assumes no responsibility for equipment installed contradictory to any code requirement or installation instructions. Careful attention has been given to the preparation of this IOM (Installation and Operation Manual) and the content has been carefully compiled for your convenience.
  • Page 3: Table Of Contents

    Section 4. Selection of Installation Location Section 5. Installation of the unit Section 5a Ceiling Mounting Section 5b Wall Mounting DIMENSIONIAL DRAWINGS FAN PERFORMANCE PHYSICAL DATA ELECTRICAL DATA WIRING DIAGRAM These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 4: Section 1. Inspection Of Packaging

    Power supply: Please refer to the label attached to the unit for correct power supply.  Minimum entering water temperature: 35.6°F  Maximum entering water temperature: 180 °F  Maximum water system pressure shall not exceed: 150 psi These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 5: Section 4. Selection Of Installation Location

    Mounting hardware diameters listed are suggestions only Local code requirements must he consulted by the installing contractor. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 6 6. Ensure there is sufficient space around he unit to service it. The dimensions shown in Figure 3 are minimum suggestions. Your application may require more space to access controls, control valves, pumps, or local code requirements. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 7: Section 5. Installation Of The Unit

    C. After the unit is secured to the lift, carefully lift the unit to the ceiling. 4. Now that the unit is at ceiling height, attach threaded rods to mounting brackets on the side of the unit. See Figure 6. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 8 All lines are to be insulated without air gaps in the insulation to prevent condensation forming resulting in an undesired leak. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 9 4. Reinstall filter grilles with the tow (2) screws in each section removed earlier. DO NOT OVER TIGHTEN. 5. Unit is now ready for contractor start-up procedures and recording of benchmark data according to all local and national requirements. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 10 Fan coil unit - CFFWA4P Series CFFWA4P Dimensional Drawing These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 11: Fan Performance

    Fan coil unit - CFFWA4P Series Fan Performance Characteristics These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 12: Physical Data

    Fan coil unit - CFFWA4P Series PHYSICAL DATA * All dimensions rounded up to nearest tenth of an inch. All dimensions are as the unit is horizontal/ceiling mounted. These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 13 Fan coil unit - CFFWA4P Series ELECTRICAL DATA HACR Circuit Breaker or Glass Fuse per circuit 208/230 -1-50/60 These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 14: Wiring Diagram

    Fan coil unit - CFFWA4P Series CFFWA4P Wiring Diagram These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.
  • Page 15 Fan coil unit - CFFWA4P Series These specifications are subject to change without notice. Check www.multiaqua.com for latest published information.

This manual is also suitable for:

Cffwa4p 08Cffwa4p 12Cffwa4p 16Cffwa4p 20

Table of Contents