Check that the AC voltage supplied at the wall outlet is within the voltage range of the AX4020 external transformer. Use a wall outlet as near as possible to the AX4020. This makes it easy to connect or disconnect the power cord.
2 - INSTALLATION This chapter provides information and instructions to install the AX4020. 2.1 - DESCRIPTION The AX4020 has the following connectors and switches on the rear panel: - 1 power switch, - 1 connector for the external power transformer cord, - 8 serial ports;...
2.2 - INSTALLATION For safety reasons, and to prevent component damage, do not connect any cable to the AX4020 once it has been powered up. Do not plug in the AX4020 power cord until all other connections have been made.
RS232 Devices ETHERNET 2.2.2 - AC Power Connection An Axel external power transformer must be used, to convert mains voltage at the wall outlet to low voltage for the AX4020. First insert the plastic moulded connector, on the external power transformer cord (ref.
AX4020. Use of any other transformer may cause permanent damage to the AX4020. 2.2.3 - Power On The power switch on the rear panel controls the power supply to the AX4020. 1 : ON 0 : OFF The green LED (ON/OFF), on the front of the AX4020, should light to indicate that it is powered up and operating correctly.
- a telnet session launched from any network point. 3.1 - FROM A SERIAL CHARACTER TERMINAL Plug a character terminal into the AX4020 Ch8 port and set up this terminal in the following way: - data transfer rate: 9600 bps...
- During set-up mode, the two leds of the Ch8 port remain lit. 3.2 - FROM A TELNET SESSION To run set-up within a telnet session, the IP address of the AX4020 must already be set. Run the telnet session from any network host. Use 4096 as the telnet port.
Note: the maximum length of a 10BaseT cable is 100 meters (330 feet). Signal Name Direction TX+ (Transmitted Data) Input TX- (Transmitted Data) Input RX+ (Received Data) Output RX- (Received Data) Output 4.1.1 - AX4020 Connected to a HUB ________________________________________________________________ Installation Guide - AX4020 Office Server...
Connector Pin Assignments 4.1.2 - AX4020 Connected to an Ethernet Controller IMPORTANT: the cable is composed of two twisted pairs. The two wires TX+ / TX- must belong to one pair and the two wires RX+ / RX- must belong to the other pair.
Connector Pin Assignments 4.2.1 - Adaptors Using an adaptor to connect a peripheral to the AX4020: # $ % & ' ( !"
Adaptor Device RJ45-DB9 Adaptor (these adaptors are shipped with the AX4020) #$$%& ' () !"...
Connector Pin Assignments 4.2.2 - Direct Connection The peripheral is directly connected to the AX4020: # $ % & ' ( !"
Device Printers, character terminals or modems (DB9) #$$%& ' () +%" Printers or character terminals (DB25) #$$%& ' ()