EmberGlow LO18NG Installation & Operation Manual page 3

Fireplace gas log tiered dual burner log set
Table of Contents

Advertisement

WARNING: Improper use or installation may cause Carbon Monoxide Poisoning. Carbon Monoxide,
is an colorless and odorless gas, and is a by- product of combustion. Caution must be taken to insure
the fireplace is properly vented when logs are in use . To avoid having potentially dangerous fumes enter
the living area, be sure the chimney is drawing pro perly and has sufficient draft.
WARNING:
Do not burn wood, solid fuels, or other material in any fireplace fitted with a gas log set.
Do not store gasoline ammable vapors and liquids in the vicinity of this or any other appliance.
Do not place clothing or other flammable material on or near the appliance.
Children and adults should be alearted to the hazards of high surface temperature and should
be kept clear to avoid burns or clothing ignition.
Young children should be carefully supervised when they are in the same room as the appliance.
Do not use this appliance if any part has been under water. Immediately call a qualified service
technician to inspect the appliance and to replace any part of the control system and any gas
control which has been under water.
A fireplace screen must be in place when appliance is operating. Unless other provisions are
made for combustion air, the fireplace screen must have provisions for combustion air.
Installation of this Energy Efficient Gas Log Set and provisions for combustion and ventilation air
must conform with the National Fuel Gas Code ANSI Z223.1/NFPA54, and any local codes.
This gas log set is only to be installed and burned in a fully vented fireplace with a fully functional
damper and chimney that is free of any obstructions. The fireplace must be constructed of non-
combustible materials and approved to burn wood.
To operate this gas log set, the fireplace damper must be fully opened and locked.
The smallest or minimum dimension of the chimney flue must be 8 inches in diameter . Do not use an
Energy efficient Gas Log Set if it is smaller than 8 inches. Do not use an Energy Efficient Gas Log Set if
fumes from the burner emerge into the room when the damper is fully open. This indicates that there is
not adequate draft for this log set and it must not be used until the fireplace draft is corrected.
This appliance must be installed with a Damper Stop Clamp (Part #14). When operating this gas log set,
the flue damper must be fully open.
The nominal inlet gas pressure for this appliance i s 7" water column for natural gas.
This appliance must also be disconnected from the gas supply system by closing its individual manual
shutoff valve during any pressure testing at pressure equal to or less than 1/2 PSIG.
FIREPLACE PREPERATION
For installation in wood-burning fireplaces only. Keep dam-
per wide open when in use. The appliance must be installed
with damper stop clamp. Minimum size chimne y flue must
be 8"with a 6" stack. (See installation instructions for further
reference to stack height and appliancedimensions).
Professionally clean chimney and fireplace floor of any
A.
combustible material to limit the smell from the system
Open fireplace damper fully and install Damper Stop
B.
Clamp with 1/4x2" set screw (Part 14#). This clamp is
Designed to allow any pilot combustion by-products to
vent (See Fig.2) Should the Damper Stop Clamp sup-
plied not fit, a permenant damper stop clamp must be
installed that will keep the damper open at a distance of
not less than 1 1/2".
The damper must be in the fully open position anytime
the unit is in operation.
Prior to connecting the gas log set, make sure that the
C.
gas supply to the fireplace is completely shut off.
d
.
PREFABRIC ATED
FIREPLACE
Figure 2. Damper stop clamp
3
PART NO. 14
MASONRY
FIREPLACE

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lo24ng

Table of Contents