ENGINE SHEET ......................Enclosed PARTS LIST / EXPLODED VIEW ................... Enclosed INSTALLATION INSTRUCTIONS .................. Enclosed WIRING DIAGRAMS BY SERIES ................... Enclosed USE ONLY HYDRO TEK CERTIFIED ORIGINAL EQUIPMENT REPLACEMENT PARTS, FAILURE TO DO SO COULD LEAD TO WARRANTY EXCLUSION AND SEVERE BODILY INJURY...
Instruction section enclosed page ensure that your new power washer exceeds the Installation Guidelines). standards set by you, the customer, by Hydro Tek engineering and management, and by our safety NO-NONSENSE GUARANTEE: Hydro certification to U.L. 1776. Systems, Inc. (Hydro Tek) promises to repair Hydro YOUR RESPONSIBILITY: This operator’s manual...
CHILDREN TO PLAY ON OR AROUND THIS EQUIPMENT. rescission of the contract of sale of any Hydro Tek product. Hydro Tek reserves the right to change or improve the design of any of its products or...
SAFETY WARNINGS panel that is at least 10” in diameter, and position 9. Transformer burner 20,000 volts. Disconnect battery cable before servicing burner or this vent to avoid water, dirt and debris collection. engine on 12-volt systems. No flammable liquids, aerosols, or flammable materials should be stored within 24”...
OPERATING INSTRUCTIONS BEFORE START UP: Read all instructions power switch to the start position only until engine 1. CHECK PUMP OIL: Check pump oil by starts. (Do not use starter fluids.) locating the oil view window. Depending on your 2. PURGE AIR FROM SYSTEM: pump model, fill to the red dot or to the top of the Squeeze the trigger on the spray gun until a site glass window.
Page 8
OPERATING INSTRUCTIONS 7. SET CHEMICAL INJECTION: other is with the chemical system on the If unit is equipped with inlet chemical injection, equipment; either downstream or high pressure place chemical pickup tube in pre-mixed chemical depending on the system you have. When using solution and open chemical valve for desired the high-pressure chemical system, do not use any chemical concentration.
Thereafter, change oil every 50 hours and the filter electrician or an authorized Hydro Tek distributor every 100 hours (see engine manual). Do not rely check for electrical problems.
If this component ruptures, you should accessories or lights to the auxiliary voltage outlet. take the machine in to an authorized Hydro Tek To extend generator life, make sure the burner and dealer. Do not plug off and continue to run.
(Part #CB100) available at your authorized to regulate the incoming Hydro Tek dealer. Perform this descaling service water supply to the pump only when a noticeable pressure drop is detected and introduce chemicals into the inlet of the pump.
If the hose is not replaced when worn or if it low volume pump which is propelled is not replaced by a Hydro Tek original equipment by the burner motor. The fuel pump hose, it may burst and serious injury and burns pressure is typically set at 100 PSI could result.
ACCESSORIES NOZZLES: The spray nozzle OPTIONAL ACCESSORIES: is a precisely machined orifice WET SANDBLASTER: The wet sandblaster is a made of hardened stainless system that introduces sand steel. The orifice size is other media such matched to the output of your baking soda) into the water machine to attain the proper flow and pressure in stream for abrasive blasting.
WARNING: Replace discharge hose with original equipment hose rated for 250°F, available at Hydro Tek dealers. HYDRO TWISTER – Surface Cleaners: The Hydro Twister® is a...
TRAILER INFORMATION TRAILERS: Hydro Tek trailers are designed to match your Hydro Tek washer and increase productivity. Several trailer tank skid TRAILER MAINTENANCE SCHEDULE configurations are available. 12 MTH. 3 MTH. 6 MTH. ITEM FUNCTION REQUIRED OR 3000 OR 6,000...
TROUBLESHOOTING GUIDE PROBABLE CAUSE REMEDY PROBLEM (The most recurring probable cause is listed first) (Repairs should only be made by a qualified technician) Power System: Gasoline or Diesel Engine Driven Engine will not start or crank over Battery dead. Charge or replace battery, add electrolyte if battery is new. Dirty battery connection.
Page 17
TROUBLESHOOTING GUIDE PROBABLE CAUSE REMEDY PROBLEM (The most recurring probable cause is listed first) (Repairs should only be made by a qualified technician) Inlet injection will not siphon chemical Check valve in strainer clogged. Clean or replace. Rinse after each use. Chemical valve not open or clogged.
TROUBLESHOOTING GUIDE BURNER TROUBLESHOOTING SC / SCU Series - 120V AC BURNER DOES BURNER DOES “NOT” COME ON “NOT” TURN OFF IS THERE FUEL IN THE TANK? !! CAUTION!! TURN UNIT OFF ADD FUEL IMMEDIATELY AND REPAIR. INSTALL SPRAY TIP, BURNER REQUIRES 1000 PSI IS THE SPRAY TIP INSTALLED? TO OPERATE, IF UNIT IS EQUIPPED w/DUAL LIGHT ON THE BURNER SWITCH TURNS OFF...
Page 19
TROUBLESHOOTING GUIDE BURNER TROUBLESHOOTING SS Series – 12V DC (also applicable to SC with 12v burners) BURNER DOES BURNER DOES “NOT” COME ON “NOT” TURN OFF IS THERE FUEL IN THE TANK? !! CAUTION!! TURN UNIT OFF ADD FUEL IMMEDIATELY AND REPAIR. INSTALL SPRAY TIP, BURNER REQUIRES 1000 PSI TO OPERATE, IF UNIT IS EQUIPPED w/DUAL IS THE SPRAY TIP INSTALLED?
MAINTENANCE INFORMATION While your pressure washer has been produced Contact your Hydro Tek dealer for maintenance. A with quality materials and craftsmanship, you as the small investment in preventative maintenance will owner have certain responsibilities for the correct add many hours to the life of your pressure washer.